RELEASE 3.02 FCP CONVERSION INSTRUCTIONS
14-25
Edition One
XC1000 Service
Enter
key. When the screen displays the
“... Stopped at
stage #: 10 Continue the Conversion (Y/N): Y”
prompt,
press the
Enter
key to continue.
c.
Continue the conversion from step 6 in section 14.9.
If the XC1000 was not at the SMT Main Menu when it was
disconnected, perform the following steps:
a. At the
C:\FCP>
prompt, type
fcpconv
and press the
Enter
key.
b. At the FCP conversion Main Menu (Figure 14-4), select
option
3. SMT Emulation
. A screen appears, requesting
confirmation of the SMT emulation parameters, with
default values that can be toggled with the space bar.
c.
Press the
End
key when done. The screen blanks.
d. Press the
Enter
key again, and the
ENTER BOOT
COMMAND:
prompt appears. Boot the XC1000 with a
0
(zero).
e.
When the PC screen displays the
Please Enter System
Manager Password:
prompt, enter the system manager
password, then press the
Enter
key.
f.
Press the
F12
key. At the FCP conversion Main Menu
(Figure 14-4), select option
2. Perform/Continue
Conversion
,
and press the
Enter
key. When the screen
displays
“... Stopped at stage #: 10 Continue the
Conversion (Y/N): Y,”
press the
Enter
key to continue.
g. Continue the conversion from step 6 in section 14.9.
11. The automatic script runs for a short time (less than 5 minutes); the
script verifies that the engineering bit is set and that system-drive 1 is
larger than or equal to system-drive 0. Also, the script checks that the
upgrade software files are compatible with the voice-processing-module
type, software releases, languages and phrases. If all verifications are
compatible, the Final confirmation before conversion screen appears.
Skip to step 12.
If any of the verifications are incompatible, the screen displays the
following error message:
“*** Conversion is not allowed ***”
and a
reason that the conversion is not allowed. The error message also
includes supporting release information for the discrepancy. Possible
reasons for not allowing a conversion are as follows:
System type is different.
Voice-processing module software release is not in the supported
list.
Language type is not supported.
Phrase UPG is not supported.
Language type is not valid.
Phrase UPGs are duplicated.
SECTION 14.9
Summary of Contents for XC1000
Page 1: ...EDITION ONE XC1000 P N 101 1345 000 SERVICE MANUAL ...
Page 8: ...CONTENTS ...
Page 19: ...1 INTRODUCTION ...
Page 30: ...2 SITE PREPARATION ...
Page 60: ...3 PLATFORM INSTALLATION ...
Page 112: ...4 STARTUP AND INITIALIZATION ...
Page 177: ...5 ROUTINE MAINTENANCE ...
Page 195: ...6 TROUBLESHOOTING ...
Page 237: ...7 STATUS LOG ...
Page 297: ...STATUS LOG 7 54 Edition One XC1000 Service ...
Page 302: ...8 REPAIR AND REPLACEMENT ...
Page 380: ...9 SYSTEM UTILITIES ...
Page 424: ...10 COMPONENT DESCRIPTIONS ...
Page 465: ...11 OPTIONAL FEATURES ...
Page 485: ...12 RELEASE 1 55 UPGRADE INSTRUCTIONS ...
Page 516: ...13 RELEASE 2 X UPGRADE INSTRUCTIONS ...
Page 559: ...14 RELEASE 3 02 FCP CONVERSION INSTRUCTIONS ...
Page 603: ...15 RELEASE 3 02 ONLINE UPGRADE INSTRUCTIONS ...
Page 631: ...16 RELEASE 3 0 SYSTEM UTILITIES ...
Page 683: ...17 RELEASE 4 X FCP CONVERSION INSTRUCTIONS r P N 281 0023 002 1 of 3 ...
Page 725: ...18 RELEASE 4 X ONLINE UPGRADE INSTRUCTIONS r P N 281 0023 002 2 of 3 ...
Page 760: ...19 RELEASE 4 0 SYSTEM UTILITIES P N 281 0023 002 Part 3 of 3 r ...
Page 776: ...20 RELEASE 4 1 SYSTEM UTILITIES P N 281 0033 000 ...
Page 787: ...APPENDIXES ...