15. MR-J3W-0303BN6 SERVO AMPLIFIER
15 - 49
Alarm No.: 33
Name: Overvoltage
Stop system: All axes
Alarm content
The voltage is 35VDC or lower when 48VDC is set for the main circuit power supply, or 15VDC or lower when
24VDC is set for the main circuit power supply.
Display
Detail name
Cause
Check method
Check result
Action
It is not repeatable.
Use a regenerative option if
it is not being used.
Increase the deceleration
time constant.
1) Lack of regenerative
capacity
Set a larger
deceleration time
constant, and then
check the repeatability.
It is repeatable.
Check 5).
The voltage is
75VDC or higher
when 48VDC is set
for the main circuit
power supply, or
55VDC or higher
when 24VDC is set
for the main circuit
power supply.
Reduce the input voltage.
33.1 Main
circuit
voltage error
2) Power supply voltage high. Check the input voltage.
The voltage is less
than 75VDC when
48VDC is set for the
main circuit power
supply, or less than
55VDC when
24VDC is set for the
main circuit power
supply.
Replace the servo
amplifier.
Summary of Contents for MELSERVO-J3W Series
Page 17: ...8 MEMO ...
Page 27: ...1 FUNCTIONS AND CONFIGURATION 1 10 MEMO ...
Page 87: ...4 STARTUP 4 14 MEMO ...
Page 117: ...5 PARAMETERS 5 30 MEMO ...
Page 129: ...6 GENERAL GAIN ADJUSTMENT 6 12 MEMO ...
Page 185: ...10 CHARACTERISTICS 10 8 MEMO ...
Page 241: ...11 OPTIONS AND AUXILIARY EQUIPMENT 11 56 MEMO ...
Page 274: ...13 USING A LINEAR SERVO MOTOR 13 25 1 2 3 4 ...