13. USING A LINEAR SERVO MOTOR
13 - 51
13.6.5 I/O setting parameters (No.PD
)
(1) Parameter list
POINT
The parameter whose symbol preceded by * can be validated with the following
conditions.
* : Turn off the power and then on again, or reset the controller after setting the
parameter.
No. Symbol
Name
Setting
(Note 1)
Factory
setting
(Note 2)
Unit
Reference
PD01
This parameter is not used. Do not change the value.
0000h
PD02 *DIA2 Input signal automatic ON selection
Each
axis
0000h This
section
(2)
PD03
This parameter is not used. Do not change the value.
0020h
PD04
0021h
PD05
0022h
PD06
0000h
PD07
*D01
Output signal device selection 1 (CN3-12 for A-axis and CN3-25 for B-axis)
Each
axis
0005h Section
5.4.2
PD08
This parameter is not used. Do not change the value.
0004h
PD09
*D03
Output signal device selection 3 (CN3-11 for A-axis and CN3-24 for B-axis)
Each
axis
0003h Section
5.4.2
PD10
This parameter is not used. Do not change the value.
0000h
PD11
0004h
PD12
0000h
PD13
0000h
PD14 *DOP3 Function selection D-3
Each
axis
0000h Section
5.4.2
PD15
This parameter is not used. Do not change the value.
0000h
PD16
0000h
PD17
0000h
PD18
0000h
PD19
0000h
PD20
0000h
PD21
0000h
PD22
0000h
PD23
0000h
PD24
0000h
PD25
0000h
PD26
0000h
PD27
0000h
PD28
0000h
PD29
0000h
PD30
0000h
PD31
0000h
PD32
0000h
Note 1. Each axis: Set a value for each of the A-axis and the B-axis.
Common: Common parameters for the A-axis and the B-axis. Set same values for the A-axis and the B-axis. If different values are
set, the last set value becomes valid.
2. Valid for the A-axis and the B-axis.
Summary of Contents for MELSERVO-J3W Series
Page 17: ...8 MEMO ...
Page 27: ...1 FUNCTIONS AND CONFIGURATION 1 10 MEMO ...
Page 87: ...4 STARTUP 4 14 MEMO ...
Page 117: ...5 PARAMETERS 5 30 MEMO ...
Page 129: ...6 GENERAL GAIN ADJUSTMENT 6 12 MEMO ...
Page 185: ...10 CHARACTERISTICS 10 8 MEMO ...
Page 241: ...11 OPTIONS AND AUXILIARY EQUIPMENT 11 56 MEMO ...
Page 274: ...13 USING A LINEAR SERVO MOTOR 13 25 1 2 3 4 ...