11. OPTIONS AND AUXILIARY EQUIPMENT
11 - 55
(3) Outline drawing
[Unit: mm]
14
1
14
1
57
Note. Values in parenthesis are the sizes when installed with a 35mm DIN rail.
11.13 Surge absorbers (recommended)
A surge absorber is required for the electromagnetic brake. Use the following surge absorber or equivalent.
When using the surge absorber, perform insulation beforehand to prevent short-circuit.
Maximum rating
Permissible circuit
voltage
Surge
immunity
Energy
immunity
Rated
power
Maximum
limit voltage
Static
capacity
(reference
value)
Varistor voltage
rating (range) V1mA
AC [Vma]
DC [V]
[A]
[J]
[W]
[A]
[V]
[pF]
[V]
140 180
(Note)
500/time
5 0.4
25
360 300
220
(198 to 242)
Note. 1 time 8 20 s
13.5
16
.5
4.7 1.0
0.8
3.
0
or
le
ss
30
.0
or
m
o
re
[Unit: mm]