14. USING A DIRECT DRIVE MOTOR
14 - 49
Alarm No.: 27
Name: Initial magnetic pole detection error
Stop system: Each axis
Alarm content
The initial magnetic pole detection was not completed properly.
Display
Detail name
Cause
Check method
Check result
Action
27.4 Magnetic
pole
detection
estimated error
1) The estimated value of
magnetic pole detection is
not correct.
Check it with the check method for alarm display "27.1".
27.5 Magnetic
pole
detection
position
deviation error
1) Position
deviation
increased during the
magnetic pole detection.
Check it with the check method for alarm display "27.1".
27.6 Magnetic
pole
detection speed
deviation error
1) Speed deviation increased
during the magnetic pole
detection.
Check it with the check method for alarm display "27.1".
27.7 Magnetic
pole
detection
current error
1) The current reached the
alarm level during the
magnetic pole detection.
Check it with the check method for alarm display "27.1".
Alarm No.: 28
Name: Encoder counter error
Stop system: Each axis
Alarm content
Data which encoder created is failure.
When the alarm occurs, startup the direct drive servo again, and then make home position setting.
Display
Detail name
Cause
Check method
Check result
Action
The shielded part is
broken.
Repair the cable.
1) Encoder cable is faulty.
Check the condition of
the shielded part.
The shielded part
has no problem.
Check 2).
Problem found.
Take countermeasures
against its cause.
2) Something near the device
caused it.
Check the noise,
ambient temperature,
etc.
No problem found.
Check 3).
2B.1 Encoder
counter error 1
3) Encoder failure
Replace the direct drive
motor, and then check
the repeatability.
It is not repeatable.
Replace the direct drive
motor.
2B.2
1) Encoder cable is faulty.
Encoder
counter error 2
2) Something near the device
caused it.
3)
Encoder
failure
Check it with the check method for alarm display "2B.1".
Alarm No.: 30
Name: Regenerative error
Stop system: All axes
Alarm content
Permissible regenerative power of the built-in regenerative resistor or regenerative option is exceeded.
A regenerative transistor in the servo amplifier is malfunctioning.
Display
Detail name
Cause
Check method
Check result
Action
30.1 Regeneration
heat error
30.2 Regenerative
transistor error
30.3 Regenerative
transistor
feedback data
error
Same as for the rotary servo motors.
Refer to section 8.3.
Summary of Contents for MELSERVO-J3W Series
Page 17: ...8 MEMO ...
Page 27: ...1 FUNCTIONS AND CONFIGURATION 1 10 MEMO ...
Page 87: ...4 STARTUP 4 14 MEMO ...
Page 117: ...5 PARAMETERS 5 30 MEMO ...
Page 129: ...6 GENERAL GAIN ADJUSTMENT 6 12 MEMO ...
Page 185: ...10 CHARACTERISTICS 10 8 MEMO ...
Page 241: ...11 OPTIONS AND AUXILIARY EQUIPMENT 11 56 MEMO ...
Page 274: ...13 USING A LINEAR SERVO MOTOR 13 25 1 2 3 4 ...