5. PARAMETERS
5 - 23
(3) Analog monitor block diagram
Droop pulses
Speed
command
Servo motor
speed
Position
control
Speed
control
PWM
Current
control
Current
command
Torque
Speed
command
Servo motor
Encoder
Current feedback
Position feedback
M
Position
command
received
from a
controller
Differ-
ential
Differ-
ential
Position feedback data
returned to a controller
Bus voltage
Current
encoder
Speed
command 2
5.3.4 Alarm history clear
The servo amplifier stores six past alarms from when its power is switched on first. To control alarms which will
occur during operation, clear the alarm history using parameter No.PC21 before starting operation.
Clearing the alarm history automatically returns to "
0".
After setting, this parameter is made valid by switch power from OFF to ON.
Alarm history clear
0: Invalid (not cleared)
1: Valid (cleared)
0 0 0
Parameter No.PC21