5. PARAMETERS
5 - 20
No.
Symbol
Name and function
Setting
Factory
setting
Unit
Setting
range
PC11
MO1
Analog monitor 1 offset
Used to set the offset voltage of the analog monitor 1 (MO1) output.
Common 0
mV 9999
to
9999
PC12
MO2
Analog monitor 2 offset
Used to set the offset voltage of the analog monitor 2 (MO2) output.
Common 0
mV
999
to
999
PC13
This parameter is not used. Do not change the value.
0
PC14
0
PC15
SNO
Station number selection
Used to select the axis to communicate with MR Configurator.
0: A-axis
1: B-axis
Common 0
PC16
This parameter is not used. Do not change the value.
0000h
PC17 **COP4 Function Selection C-4
This parameter cannot be used in the speed control mode and the torque
control mode.
This is used to select a home position setting condition.
Selection of home position setting condition
0: Need to pass motor Z-phase after the power
supply is switched on.
1: Not need to pass motor Z-phase after the power
supply is switched on.
0 0 0
Each
axis
0000h Refer
to
Name
and
function
column.
PC18
This parameter is not used. Do not change the value.
0000h
PC19
0000h
PC20
0000h
PC21
*BPS Alarm history clear
Used to clear the alarm history.
Alarm history clear
0: Invalid
1: Valid
When alarm history clear is made valid, the alarm
history is cleared at next power-on.
After the alarm history is cleared, the setting is
automatically made invalid (reset to 0).
0 0 0
Each
axis
0000h Refer
to
Name
and
function
column.
PC22
This parameter is not used. Do not change the value.
0000h
PC23
0000h
PC24
0000h
PC25
0000h
PC26
0000h
PC27
0000h
PC28
0000h
PC29
0000h
PC30
0000h
PC31
0000h
PC32
0000h
Summary of Contents for MELSERVO-J3W Series
Page 17: ...8 MEMO ...
Page 27: ...1 FUNCTIONS AND CONFIGURATION 1 10 MEMO ...
Page 87: ...4 STARTUP 4 14 MEMO ...
Page 117: ...5 PARAMETERS 5 30 MEMO ...
Page 129: ...6 GENERAL GAIN ADJUSTMENT 6 12 MEMO ...
Page 185: ...10 CHARACTERISTICS 10 8 MEMO ...
Page 241: ...11 OPTIONS AND AUXILIARY EQUIPMENT 11 56 MEMO ...
Page 274: ...13 USING A LINEAR SERVO MOTOR 13 25 1 2 3 4 ...