15. MR-J3W-0303BN6 SERVO AMPLIFIER
15 - 72
(2) Replacement procedure
MR-J3W03BTCBL03M
CN2A
or
CN2B
Servo amplifier
New MR-J3BAT
MR-J3BAT
for backup
Old MR-J3BAT
CN4
Step 1
Connect MR-J3BAT for backup to the battery connector of
MR-J3W03BTCBL03M.
New MR-J3BAT
MR-J3BAT
for backup
(Note)
CN4
MR-J3W03BTCBL03M
CN2A
or
CN2B
Servo amplifier
Step 2
Remove old MR-J3BAT from the servo amplifier.
Note. When replacing MR-J3BAT, connect/disconnect the junction-side
connector.
Servo amplifier
MR-J3BAT
for backup
New MR-J3BAT
MR-J3W03BTCBL03M
CN4
CN2A
or
CN2B
Step 3
Mount new MR-J3BAT to the servo amplifier. Connect the
lead wire plug of MR-J3BAT to the battery extension cable
connected to the CN4 connector of the servo amplifier.
Servo amplifier
MR-J3BAT
for backup
New MR-J3BAT
MR-J3W03BTCBL03M
CN4
CN2A
or
CN2B
Step 4
Remove the MR-J3BAT for backup from the battery
connector of MR-J3W03BTCBL03M, and the procedure is
completed.