5. PARAMETERS
5 - 6
5.1.7 Auto tuning
Parameter
No. Symbol
Name
Setting
Factory
setting
Unit
Setting
range
PA08
ATU
Auto tuning mode
Each axis
0001h
Refer to
the text.
PA09
RSP
Auto tuning response
Each axis
12
1 to 32
POINT
This parameter cannot be used in the torque control mode.
Make gain adjustment using auto tuning. Refer to section 6.2 for details.
(1) Auto tuning mode (parameter No.PA08)
Select the gain adjustment mode.
Gain adjustment mode setting
Parameter No.PA08
0 0 0
Setting Gain adjustment mode Automatically set parameter No. (Note)
Interpolation mode
Auto tuning mode 1
Auto tuning mode 2
Manual mode
0
1
2
3
PB06 PB08 PB09 PB10
PB06 PB07 PB08 PB09 PB10
PB07 PB08 PB09 PB10
Note. The parameters have the following names.
Parameter No.
Name
PB06
Load to motor inertia moment ratio
PB07
Model loop gain
PB08
Position loop gain
PB09
Speed loop gain
PB10
Speed integral compensation