11. OPTIONS AND AUXILIARY EQUIPMENT
11 - 54
11.12 Junction terminal block MR-TB26A
(1) Usage
When using a junction terminal block (MR-TB26A), always use it with a junction terminal block cable (MR-
TBNATBL M).
To use a junction terminal block, mount it to the DIN rail.
Cable length
05: 0.5m
1 : 1m
Terminal numbers on a junction terminal block correspond with the pin numbers on the CN3 connector of a
servo amplifier.
The terminal symbol S is for the shield.
Junction terminal
block
MR-TB26A
Junction terminal block cable
(MR-TBNATBL M)
CN3
Servo amplifier
Ground the junction terminal block cable using the S terminal of the junction terminal block.
(2) Specifications
Junction terminal block
Item
MR-TB26A
Rating AC/DC32V
0.5A
Twisted wire
0.08 to 1.5mm
2
(AWG28 to AWG14)
Usable cables
Solid wire
0.32 to 1.2mm
Wire sheath outer diameter Wire with 3.4mm or less
Tool
210-619 (WAGO Company of Japan, LTD.) or equivalent
210-119SB (WAGO Company of Japan, LTD.) or equivalent
Stripped length
5 to 6mm