14. USING A DIRECT DRIVE MOTOR
14 - 6
CAUTION
When using the regenerative resistor, switch power off with the alarm signal.
Otherwise, a transistor fault or the like may overheat the regenerative resistor,
causing a fire.
Do not modify the equipment.
Connect the servo amplifier power output (U, V, and W) to the direct drive motor
power input (U, V, and W) directly. Do not let a magnetic contactor, etc. intervene.
Otherwise, it may cause a malfunction.
U
Direct drive motor
M
V
W
U
V
W
Servo amplifier
U
M
V
W
U
V
W
Servo amplifier
Direct drive motor
14.3.1 Notes of this chapter
This chapter does not include the following items. For the items, refer to the corresponding sections below.
Item Reference
Explanation of power supply system
Section 3.3
Signal (device) explanations
Section 3.5
Alarm occurrence timing chart
Section 3.6
Interface
Section 3.7 (except internal connection
diagrams)
Treatment of cable shield external
conductor
Section 3.8
SSCNET cable connection
Section 3.9
Grounding Section
3.12
Control axis selection
Section 3.13
Summary of Contents for MELSERVO-J3W Series
Page 17: ...8 MEMO ...
Page 27: ...1 FUNCTIONS AND CONFIGURATION 1 10 MEMO ...
Page 87: ...4 STARTUP 4 14 MEMO ...
Page 117: ...5 PARAMETERS 5 30 MEMO ...
Page 129: ...6 GENERAL GAIN ADJUSTMENT 6 12 MEMO ...
Page 185: ...10 CHARACTERISTICS 10 8 MEMO ...
Page 241: ...11 OPTIONS AND AUXILIARY EQUIPMENT 11 56 MEMO ...
Page 274: ...13 USING A LINEAR SERVO MOTOR 13 25 1 2 3 4 ...