5. PARAMETERS
5 - 3
5.1.2 Parameter write inhibit
Parameter
No. Symbol
Name
Setting
Factory
setting
Unit
Setting
range
PA19
*BLK Parameter write inhibit
Each axis
000Bh
Refer to
the text.
POINT
Turn off the power and then on again, or reset the controller after setting the
parameter to validate the parameter value.
In the factory setting, this servo amplifier allows changes to the basic setting parameter, gain/filter parameter
and extension setting parameter settings. With the setting of parameter No.PA19, write can be disabled to
prevent accidental changes.
The following table indicates the parameters which are enabled for reference and write by the setting of
parameter No.PA19. Operation can be performed for the parameters marked .
Parameter No.
PA19 setting
Setting
operation
Basic setting
parameters
No.PA
Gain/filter
parameters
No.PB
Extension
setting
parameters
No.PC
I/O setting
parameters
No.PD
(Note)
Special setting
parameters
No.PS
Option setting
parameters
No.Po
Reference
0000h
Write
Reference
000Bh
(factory setting)
Write
Reference
000Ch
Write
Reference
000Dh
Write
Reference
000Eh
Write
Reference
100Bh
Write
No.PA19
only
Reference
100Ch
Write
No.PA19
only
Reference
100Dh
Write
No.PA19
only
Reference
100Eh
Write
No.PA19
only
Note. Do not use this parameter when using a rotary servo motor.
Summary of Contents for MELSERVO-J3W Series
Page 17: ...8 MEMO ...
Page 27: ...1 FUNCTIONS AND CONFIGURATION 1 10 MEMO ...
Page 87: ...4 STARTUP 4 14 MEMO ...
Page 117: ...5 PARAMETERS 5 30 MEMO ...
Page 129: ...6 GENERAL GAIN ADJUSTMENT 6 12 MEMO ...
Page 185: ...10 CHARACTERISTICS 10 8 MEMO ...
Page 241: ...11 OPTIONS AND AUXILIARY EQUIPMENT 11 56 MEMO ...
Page 274: ...13 USING A LINEAR SERVO MOTOR 13 25 1 2 3 4 ...