6. GENERAL GAIN ADJUSTMENT
6 - 6
6.2.4 Response level setting in auto tuning mode
Set the response (The first digit of parameter No.PA09) of the whole servo system. As the response level setting
is increased, the track ability and settling time for a command decreases, but a too high response level will
generate vibration. Hence, make setting until desired response is obtained within the vibration-free range.
If the response level setting cannot be increased up to the desired response because of machine resonance
beyond 100Hz, machine resonance suppression filter (parameter No.PB01, PB13 to PB16) may be used to
suppress machine resonance. Suppressing machine resonance may allow the response level setting to
increase. Refer to section 7.2 for filter tuning mode and machine resonance suppression filter.
Setting of parameter No.PA09
Machine characteristic
Response level setting
Machine rigidity
Machine resonance
frequency guideline
Guideline of corresponding machine
1 Low
10.0
2 11.3
3 12.7
4 14.3
5 16.1
6 18.1
7 20.4
8 23.0
9 25.9
10 29.2
11 32.9
12 37.0
13 41.7
14 47.0
15
52.9
16 Middle
59.6
17 67.1
18 75.6
19 85.2
20 95.9
21 108.0
22 121.7
23 137.1
24 154.4
25 173.9
26 195.9
27 220.6
28 248.5
29 279.9
30 315.3
31
355.1
32 High
400.0
Large conveyor
Arm robot
General machine
tool conveyor
Precision
working
machine
Inserter
Mounter
Bonder
Summary of Contents for MELSERVO-J3W Series
Page 17: ...8 MEMO ...
Page 27: ...1 FUNCTIONS AND CONFIGURATION 1 10 MEMO ...
Page 87: ...4 STARTUP 4 14 MEMO ...
Page 117: ...5 PARAMETERS 5 30 MEMO ...
Page 129: ...6 GENERAL GAIN ADJUSTMENT 6 12 MEMO ...
Page 185: ...10 CHARACTERISTICS 10 8 MEMO ...
Page 241: ...11 OPTIONS AND AUXILIARY EQUIPMENT 11 56 MEMO ...
Page 274: ...13 USING A LINEAR SERVO MOTOR 13 25 1 2 3 4 ...