15. MR-J3W-0303BN6 SERVO AMPLIFIER
15 - 30
(d) Main circuit power supply off
Main circuit power supply off causes Undervoltage alarm (10) and will be (c) of this section.
(e) Control circuit power supply off
POINT
While the control circuit power supply is off, the dynamic brake does not operate.
Coasting
(20ms)
Electromagnetic brake
Electromagnetic brake
operation delay time
Control circuit
power supply
ON
OFF
Servo motor speed
(f) Ready-off command from controller
Dynamic brake
Dynamic brake
Electromagnetic brake
Electromagnetic brake
Electromagnetic
brake interlock
(MBR-A/MBR-B)
Dynamic brake
enabled time
Electromagnetic brake
operation delay time
(Note) ON
OFF
Base circuit
ON
OFF
Servo motor speed
Ready-on command
(For controller)
No
Yes
(ON)
(OFF)
Note. ON: Electromagnetic brake is not activated.
OFF: Electromagnetic brake is activated.