3. SIGNALS AND WIRING
3 - 34
(3) Alarm occurrence
(Note)
Electromagnetic
brake interlock
(MBR-A/MBR-B)
ON
OFF
Base circuit
Servo motor speed
Alarm
No
Yes
ON
OFF
(ON)
(OFF)
(10ms)
Dynamic brake
Dynamic brake
Electromagnetic brake
Electromagnetic brake
Electromagnetic brake
operation delay time
Note. ON: Electromagnetic brake is not activated.
OFF: Electromagnetic brake is activated.
(4) Both main and control circuit power supplies off
(Note 2)
Electromagnetic
brake interlock
(MBR-A/MBR-B)
ON
OFF
Base circuit
Servo motor speed
Alarm
No
Yes
ON
OFF
(ON)
(OFF)
Electromagnetic brake
operation delay time
(Note 2)
ON
OFF
Main circuit
Control circuit power
(10ms)
Dynamic brake
Dynamic brake
Electromagnetic brake
Electromagnetic brake
10ms
(Note 1)
15 to 100ms
Note 1. Changes with the operating status.
2. ON: Electromagnetic brake is not activated.
OFF: Electromagnetic brake is activated.