13. USING A LINEAR SERVO MOTOR
13 - 52
(2) List of details
No. Symbol
Name
Setting
Factory
setting
Unit
Setting
range
PD02 *DIA2 Input signal automatic ON selection
Select the input devices to be automatically turned ON.
0
BIN 0: Used as external input signal
BIN 1: Automatic ON
Factory setting
BIN
HEX
Signal name
0
0
0
Upper stroke limit
(FLS)
0
0
0 0
Lower stroke limit
(RLS)
For example, to turn ON RLS, the setting is "
2".
When the upper stroke limit (FLS) or the lower stroke limit (RLS) is used on the
controller side, do not set to automatically ON since the magnetic pole detection
signal is shared with the input signal.
Each
axis
0000h Refer
to
name
and
function
column.
13.6.6 Special setting parameters (No.PS
)
(1) Parameter list
POINT
The parameter whose symbol preceded by * can be validated with the following
conditions.
* : Turn off the power and then on again, or reset the controller after setting the
parameter.
**: Turn off the power and then on again after setting the parameter.
No. Symbol
Name
Setting
(Note 1)
Factory
setting
(Note 2)
Unit
Reference
PS01 **LIT1 Linear function selection 1
Each
axis
0301h
PS02
**LIM Linear encoder resolution setting Numerator
Each
axis
1000
PS03
**LID Linear encoder resolution setting Denominator
Each
axis
1000
This
section
(2)
PS04
*LIT2 Linear function selection 2
Each
axis
0003h
PS05
LB1
Linear servo motor control position deviation error detection level
Each
axis
0 mm
PS06
LB2
Linear servo motor control speed deviation error detection level
Each
axis
0 mm/s
PS07
LB3
Linear servo motor control thrust deviation error detection level
Each
axis
100
Summary of Contents for MELSERVO-J3W Series
Page 17: ...8 MEMO ...
Page 27: ...1 FUNCTIONS AND CONFIGURATION 1 10 MEMO ...
Page 87: ...4 STARTUP 4 14 MEMO ...
Page 117: ...5 PARAMETERS 5 30 MEMO ...
Page 129: ...6 GENERAL GAIN ADJUSTMENT 6 12 MEMO ...
Page 185: ...10 CHARACTERISTICS 10 8 MEMO ...
Page 241: ...11 OPTIONS AND AUXILIARY EQUIPMENT 11 56 MEMO ...
Page 274: ...13 USING A LINEAR SERVO MOTOR 13 25 1 2 3 4 ...