15. MR-J3W-0303BN6 SERVO AMPLIFIER
15 - 18
Table 15.1 Connector and applicable wire
Connector
applications
Receptacle assembly
Applicable wire
size
Stripped length
[mm]
Open tool
Manufacturer
For CNP1
FK-MCP1.5/4-ST-3.5 or
equivalent
AWG24 to
AWG16
9 -
Phoenix
Contact
(b) Cable connection procedure
1) Termination of the cables
Solid wire: After the sheath has been stripped, the cable can be used as it is.
Sheath Core wires
Approx. 9mm
Twisted wire: Use the cable after stripping the sheath without twisting the core. At this time, take
care to avoid a short caused by the loose wires of the core and the adjacent pole. Do not solder
the core as it may cause a contact fault.
2) Inserting wire
a) Solid wire
Insert the cable to the end.
Solid wire
b) Stranded wire
Insert the wire to the end with pushing down the button with a small flat head screwdriver, etc.
Release button
Stranded wire