12. ABSOLUTE POSITION DETECTION SYSTEM
12 - 6
(2) Installation of MR-BAT
Battery holder 1
Securely insert MR-BAT to the battery holder 1.
CON1
Push the MR-BAT connector into CON1.
Confirm the click sound at this point.
The connector has to be connected in the right direction.
If the connector is pushed forcefully in the wrong direction,
the connector will break.
Duct
Place the MR-BAT lead wire to the duct designed to store
lead wires.
Install other seven MR-BATs in the same manner.
Bring out the lead wire from the space between the ribs, and bend it as
shown above to store it in the duct. Connect the lead wire to the
connector. Be careful not to get the lead wire caught in the case or
other parts.