PB13
NH1
Machine resonance suppression filter 1
Set the notch frequency of the machine resonance suppression filter 1.
When the parameter No.PB01 setting is "
0", the setting of this parameter
is ignored.
If a value exceeding "3000" is set for this parameter, it is automatically rewritten
as "3000".
Each
axis
4500 Hz 100
to
4500
PB14 NHQ1 Notch shape selection 1
Select the shape of the machine resonance suppression filter 1.
Notch depth selection
Setting value
Depth
Gain
0
Deep
1
14dB
2
8dB
3
4dB
Shallow
Notch width
Setting value
Width
0
2
Standard
1
3
2
4
3
5
Wide
0
0
to
to
40dB
When the parameter No.PB01 setting is "
0", the setting of this parameter
is ignored.
Each
axis
0000h Refer
to
Name
and
function
column.
PB15
NH2
Machine resonance suppression filter 2
Set the notch frequency of the machine resonance suppression filter 2.
Set parameter No.PB16 (notch shape selection 2) to "
1" to make this
parameter valid.
If a value exceeding "3000" is set for this parameter, it is automatically rewritten
as "3000".
Each
axis
4500 Hz 100
to
4500
PB16 NHQ2 Notch shape selection 2
Select the shape of the machine resonance suppression filter 2.
5
3
4
Notch depth selection
Setting value Depth
Gain
0
40dB
Deep
1
14dB
2
8dB
3
4dB
Shallow
to
Notch width
Setting value
Width
0
2
Standard
1
2
3
Wide
to
0
Machine resonance suppression filter 2 selection
0: Invalid
1: Valid
Each
axis
0000h Refer
to
Name
and
function
column.
Summary of Contents for MELSERVO-J3W Series
Page 17: ...8 MEMO ...
Page 27: ...1 FUNCTIONS AND CONFIGURATION 1 10 MEMO ...
Page 87: ...4 STARTUP 4 14 MEMO ...
Page 117: ...5 PARAMETERS 5 30 MEMO ...
Page 129: ...6 GENERAL GAIN ADJUSTMENT 6 12 MEMO ...
Page 185: ...10 CHARACTERISTICS 10 8 MEMO ...
Page 241: ...11 OPTIONS AND AUXILIARY EQUIPMENT 11 56 MEMO ...
Page 274: ...13 USING A LINEAR SERVO MOTOR 13 25 1 2 3 4 ...