5-34 Image Optimization
Display Format
Description
This function is to adjust the display of the image.
Operation
Adjust through the [Display Format] item in the menu.
5.8.1.3 Exit
In Free Xros M mode, tap [Free Xros M] or [B] to exit.
5.9
TDI
TDI mode is intended to provide information of low-velocity tissue motion, specifically for cardiac
movement.
There are 4 types of TDI mode:
Tissue Velocity Imaging (TVI): This imaging mode is used to detect tissue movement with
direction and speed information.
Tissue Energy Imaging (TEI): This imaging mode reflects the status of cardiac movement
by displaying the intensity of tissue, the brighter the color the less the intensity.
Tissue Velocity Doppler Imaging (TVD): This imaging mode provides direction and speed
information of the tissue quantificationally with doppler spectrum.
Tissue Velocity M Imaging (TVM): This function assists to observe the cardiac motion
through a direct angle. TVM mode is also called Color Tissue M mode, refer to "5.10 Color
M Mode" for details.
Only phased probe is valid for TDI function.
5.9.1 TDI Exam Protocol
In real-time mode, tap [TDI] on the right side of the operating panel to enter the corresponding
TDI mode as follows:
In B or B+Color mode, tap to enter TVI mode.
In Power mode, tap to enter TEI mode.
In PW mode, tap to enter TVD sampling line adjustment status.
In M mode, tap to enter TVM sampling line adjustment status.
Switching between the TDI modes
In TDI mode, tap [Color], [Power], [M] or [PW] to switch between the modes.
Exit TDI
Tap [TDI] to exit TDI mode and enter general imaging modes.
Or, tap [B] to return to B mode directly.
Summary of Contents for TE5
Page 1: ...TE7 TE5 Diagnostic Ultrasound System Operator s Manual Basic Volume ...
Page 2: ......
Page 6: ......
Page 12: ......
Page 24: ......
Page 36: ......
Page 54: ......
Page 110: ......
Page 115: ...Display Cine Review 6 5 6 Tap Return on the screen or tap Freeze to exit image compare ...
Page 120: ......
Page 124: ......
Page 156: ......
Page 174: ......
Page 192: ...12 18 Setup Select Advanced and do as follows Select MAPS and do as follows ...
Page 202: ...13 2 Probes and Biopsy C5 2s L12 4s L7 3s P4 2s L14 6s C11 3s L14 6Ns V11 3Ws P7 3Ts 7LT4s ...
Page 226: ...13 26 Probes and Biopsy NGB 034 NGB 035 ...
Page 250: ......
Page 272: ......
Page 276: ...A 4 Wireless LAN Tap Add Manually create a network profile to set ...
Page 282: ......
Page 318: ......
Page 322: ......
Page 323: ...P N 046 006959 07 1 0 ...