2.5 Causes and countermeasures for ELECYLINDER alarms
C2-36
ME0384-4A
C
ha
pt
er
2
Troubl
es
hoot
ing
M
ai
nt
ena
nc
e
Sec
tion
[Warning: Maintenance warning 3]
This is an alert that the target value of the "overload warning level" set by the customer has been
reached.
No.
Content
Causes and countermeasures
1
Before the ELECYLINDER stops operation due
to the "overload alarm", follow the
troubleshooting procedure and conduct visual
inspection and maintenance.
* To disable this warning, change the "overload
warning level" in "Maintenance Information" to
100%.
[Causes]
The warning may be caused by the depletion of
grease on the ball screw/guide inside the
ELECYLINDER, intrusion of foreign matter,
brake failure, motor failure, contact with
peripheral equipment, etc.
[Countermeasure 1]
Visually check for the depletion of grease on the
ball screw/guide inside the ELECYLINDER,
intrusion of foreign matter, etc.
If this is the case, clean the inside of the
ELECYLINDER and replenish the grease.
→
Refer to the instruction manual of each
ELECYLINDER for the cleaning method.
Countermeasure 2]
Remove the motor and check the sliding
movement of the ELECYLINDER body.
If there is no abnormality in the sliding motion,
there is a possibility of motor or brake failure.
Replacement of the motor is recommended.
For some models, the motor cannot be replaced
by the customer. In that case, please contact us.
* For details on the maintenance warning settings, see "1.4 Maintenance Information" in
"Maintenance Section".
Summary of Contents for Rcon
Page 12: ...ME0384 4A ...
Page 32: ...Actuator Coordinate System Intro 20 ME0384 4A ...
Page 42: ...1 3 General Specifications A1 9 ME0384 4A Specifications Section Chapter 1 RCON Overview ...
Page 45: ...ME0384 4A ...
Page 291: ...ME0384 4A ...
Page 323: ...ME0384 4A ...
Page 384: ...1 3 Startup Procedure B1 9 ME0384 4A Startup Section Chapter 1 Overview ...
Page 420: ...3 6 Precautions B3 15 ME0384 4A Startup Section Chapter 3 Absolute Reset ...
Page 588: ...6 2 Various Functions B6 81 ME0384 4A Startup Section ...
Page 837: ......
Page 838: ......