Caution when Connecting EC Connection Unit
Described below is the caution notes when the gateway unit and the EC connection unit are
connected.
●
The EC connection unit occupies domains for four axes (one word) even though not all of four
axes are connected. Also, an axis number that an axis is not connected should not be pulled
one number forward.
●
The axis numbers for the EC connection unit should be assigned from after axes connected to
driver units (RCON-PC/AC/DC/PC/SC) and SCON extension unit.
●
The EC connection unit can be connected for four units at maximum, however, it cannot be
connected if the top axis number exceeds 0 to 15 and an alarm should get generated.
●
When the EC connection unit is connected, the initialization time should be longer compared to
when only the driver unit is connected (by approx. 60msec).
●
For the structure with driver units and EC connection units existing together, communication
from a teaching tool to EC connection units and ELECYLINDER will not start unless the
initialization communication to all the units has finished.
[Initializing Communication when EC Connection Unit Existed Together]
●
Time taken for the movement command (ST* Signal) reaching from PLC to ELECYLINDER
should be approximately 20msec.
●
When the EC connection unit is connected, the time taken for data update for the PC software
should be longer compared to when only the driver unit is connected in the structure.
(1)
Finish initializing communication
with driver units and SCON-CB
conducted first
(2) Initializing communication for EC connection units
starts
When
communication of (1)
failed and did not finish in normal condition,
communication in (2)
would not start.
Without completing communications in
(1) and
(2)
,
(3) communication from teaching tool to EC connection unit and
ELECYLIDER
should not be conducted.
* Communication from teaching tool to gateway unit should be available.
Teaching Tool
ELECYLINDER
ELECYLINDER
ELECYLINDER
Driver
Unit
EC
Connection
Unit
SC
ON
E
xte
ns
ion
U
nit
SCON-CB
(RCON Connection Type)
G
at
ew
ay
un
it
Ter
m
ina
l U
ni
t
Summary of Contents for Rcon
Page 12: ...ME0384 4A ...
Page 32: ...Actuator Coordinate System Intro 20 ME0384 4A ...
Page 42: ...1 3 General Specifications A1 9 ME0384 4A Specifications Section Chapter 1 RCON Overview ...
Page 45: ...ME0384 4A ...
Page 291: ...ME0384 4A ...
Page 323: ...ME0384 4A ...
Page 384: ...1 3 Startup Procedure B1 9 ME0384 4A Startup Section Chapter 1 Overview ...
Page 420: ...3 6 Precautions B3 15 ME0384 4A Startup Section Chapter 3 Absolute Reset ...
Page 588: ...6 2 Various Functions B6 81 ME0384 4A Startup Section ...
Page 837: ......
Page 838: ......