3.8 I/O Signals
A3-106
ME0384-4A
Chapt
er 3 G
at
eway
Uni
t
Spec
ific
at
ion
s S
ec
tion
[12] Jog/inching switching (JISL)
PLC output signal
Operation mode Direct numerical control Simple direct Positioner 1 Positioner 2 Positioner 3 Positioner 5
○
: Y
×
: N
○
○
○
○
×
○
It is a switching signal between jog operation and inching (incremental) operation.
When JISL signal is OFF : Jog operation
When JISL signal is ON : Inching operation
If the JISL signal is switched to ON (inching) during jog operation, it decelerates and stops, and
switches to the inching function.
If the JISL signal is switched to OFF (jog) during inching operation, it switches to the jog function
after the travel is completed.
Jog operation
Inching operation
JISL
OFF
ON
JVEL
= OFF
Speed
Parameter No. 26 "Jog velocity"
Parameter No. 26 "Jog velocity"
Travel distance
-
Parameter No. 48 "Inching"
Acceleration/
deceleration Rated value (dependent on actuator) Rated value (dependent on actuator)
JVEL
= ON
Speed
Parameter No. 47 "Jog velocity 2"
(Note 1)
Parameter No. 47 "Jog velocity 2"
Travel distance
-
Parameter No. 49 "Inching 2"
Acceleration/
deceleration Rated value (dependent on actuator) Rated value (dependent on actuator)
Operation
While JOG+ / JOG- is ON
When the rising edge (ON edge)
of JOG+ / JOG- is detected
Note 1: For direct numerical control mode, it operates at the following speed.
When speed setting value = 0 : operates at the value of parameter No. 47 "PIO Jog velocity 2"
When speed setting value ≠ 0
: operates at the speed set value
(For details, see "3.7 Address Configuration / Direct numerical control mode assignment
(page A3-64).")
Summary of Contents for Rcon
Page 12: ...ME0384 4A ...
Page 32: ...Actuator Coordinate System Intro 20 ME0384 4A ...
Page 42: ...1 3 General Specifications A1 9 ME0384 4A Specifications Section Chapter 1 RCON Overview ...
Page 45: ...ME0384 4A ...
Page 291: ...ME0384 4A ...
Page 323: ...ME0384 4A ...
Page 384: ...1 3 Startup Procedure B1 9 ME0384 4A Startup Section Chapter 1 Overview ...
Page 420: ...3 6 Precautions B3 15 ME0384 4A Startup Section Chapter 3 Absolute Reset ...
Page 588: ...6 2 Various Functions B6 81 ME0384 4A Startup Section ...
Page 837: ......
Page 838: ......