3.8 I/O Signals
A3-147
ME0384-4A
Spec
ifi
cat
ion
s
Sec
tion
Chapt
er 3 G
at
eway
Uni
t
The torque (current limit value) configured for [Pressing force] in the Simple Data Setting screen
judges completion of pressing operation.
When the ELECYLINDER is performing pressing operation, satisfying the following conditions
will produce a judgment of pressing complete, turning ON the PE signal.
(Accumulated time in which current has reached pressing value [%]) -
(Accumulated time in which current
is less than pressing value [%]) ≥ 255ms
Points of caution for when the workpiece is not struck (no contact) and the movement to forward
end or backward end is complete. Consider a master device sequence or detection method
based on the content below.
●
If no contact is made, the PE signal will not turn ON.
A timer is required to determine if no contact has been made.
●
After a non-contact operation, the unit will stop in the pressing operation status.
●
If the workpiece shifts once pressing complete is determined and the PE signal is ON,
the ELECYLINDER will start another approach operation with the PE signal still ON. If the
workpiece cannot be pressed again, it will remain ON even with no contact.
Reference
Reference
Current
Time
Pressing [%]
Operation
start
Approach operation end
Pressing start
200ms
20ms
75ms
295ms
200ms + 75ms -
20ms ≥ 255ms
Pressing complete (PE output)
Contacting
workpiece
Decrease in current due to
movement of workpiece
Summary of Contents for Rcon
Page 12: ...ME0384 4A ...
Page 32: ...Actuator Coordinate System Intro 20 ME0384 4A ...
Page 42: ...1 3 General Specifications A1 9 ME0384 4A Specifications Section Chapter 1 RCON Overview ...
Page 45: ...ME0384 4A ...
Page 291: ...ME0384 4A ...
Page 323: ...ME0384 4A ...
Page 384: ...1 3 Startup Procedure B1 9 ME0384 4A Startup Section Chapter 1 Overview ...
Page 420: ...3 6 Precautions B3 15 ME0384 4A Startup Section Chapter 3 Absolute Reset ...
Page 588: ...6 2 Various Functions B6 81 ME0384 4A Startup Section ...
Page 837: ......
Page 838: ......