6.1 Parameter
B6-36
ME0384-4A
St
art
up
Se
ctio
n
[Vibration Suppression No. Initial Value (Parameter No. 109)]
No.
Name
Unit
Input range
Default initial value setting
109 Vibration suppression No.
initial value
-
0 to 3
0
A parameter dedicated to vibration damping control.
For details, refer to "6.2 Various Functions/Vibration damping control function (page B6-65)".
[Stop Method During SrvOFF (Parameter No. 110)]
No.
Name
Unit
Input range
Default initial value setting
110 Stop method during
SrvOFF
-
0: Sudden stop
1: Decelerating stop
0
Selects Servo OFF command, drive source cutoff, and stop mode of actuator during alarm
generation (operation cancel level).
Stop command
Set value
0
: Sudden stop
1
: Decelerating stop
During
vibration
control
During
normal
positioning
control
During
vibration
control
During normal
positioning
control
Pausing
Vibration control
decelerating
stop
Normal
decelerating
stop
Vibration
control
decelerating
Stop
Normal
decelerating
Stop
Servo OFF
Sudden stop with emergency
stop torque
Drive-source cutoff
Alarm
(Operation cancel level)
Alarm
(Cold start)
Sudden stop with emergency stop torque
AC servo motor specification only
Summary of Contents for Rcon
Page 12: ...ME0384 4A ...
Page 32: ...Actuator Coordinate System Intro 20 ME0384 4A ...
Page 42: ...1 3 General Specifications A1 9 ME0384 4A Specifications Section Chapter 1 RCON Overview ...
Page 45: ...ME0384 4A ...
Page 291: ...ME0384 4A ...
Page 323: ...ME0384 4A ...
Page 384: ...1 3 Startup Procedure B1 9 ME0384 4A Startup Section Chapter 1 Overview ...
Page 420: ...3 6 Precautions B3 15 ME0384 4A Startup Section Chapter 3 Absolute Reset ...
Page 588: ...6 2 Various Functions B6 81 ME0384 4A Startup Section ...
Page 837: ......