3.7 Address Configuration
A3-85
ME0384-4A
Spec
ifi
cat
ion
s
Sec
tion
Chapt
er 3
G
at
eway
Uni
t
(1) Backward End / Forward End [mm]
It is the coordinate values for positioning. Input values from the home position.
Registration is available in 0.01mm unit.
(2) Acceleration / Velocity / Deceleration
●
Acceleration [% or G]
Acceleration at the start of operation should be set in a value from 1 to 100%.
Touch [Switch Unit] and the unit switches to G and can be registered in 0.01G unit.
●
Velocity [% or mm/s]
The velocity to perform the positioning operation should be set in a value from 1 to 100%
If there is a check mark at “Pressing”, it should be the movement speed from the movement
start position (forward end or backward end) to the pressing start position.
When the velocity is set to a value lower than the pressing speed, the pressing operation
should be performed in the set velocity. The pressing speed should differ depending on the
models. Refer to an instruction manual of each ELECYLINDER or a catalog for detail.
Touch [Switch Unit] and the unit switches to mm/s and can be registered in 0.01mm/s unit.
●
Deceleration [% or G]
Deceleration at the stop of operation should be set in a value from 1 to 100%.
If there is a check mark at “Pressing”, it should be the deceleration from the movement start
position (forward end or backward end) to the pressing start position.
Touch [Switch Unit] and the unit switches to G and can be registered in 0.01G unit
.
Caution
In case there is any abnormal noise, vibration or mechanical shock in operation of
ELECYLINDER, revise and decrease the acceleration and deceleration.
Continuing to use without revising could cause malfunction.
Summary of Contents for Rcon
Page 12: ...ME0384 4A ...
Page 32: ...Actuator Coordinate System Intro 20 ME0384 4A ...
Page 42: ...1 3 General Specifications A1 9 ME0384 4A Specifications Section Chapter 1 RCON Overview ...
Page 45: ...ME0384 4A ...
Page 291: ...ME0384 4A ...
Page 323: ...ME0384 4A ...
Page 384: ...1 3 Startup Procedure B1 9 ME0384 4A Startup Section Chapter 1 Overview ...
Page 420: ...3 6 Precautions B3 15 ME0384 4A Startup Section Chapter 3 Absolute Reset ...
Page 588: ...6 2 Various Functions B6 81 ME0384 4A Startup Section ...
Page 837: ......
Page 838: ......