5.1 Operation Confirmation with PC Software
B5-3
ME0384-4A
St
ar
tu
p
Se
ct
io
n
(6) If "300: Communication port open error"
screen is displayed, communication
connection has failed.
The following causes may be
possible, so review the procedure
from item
1
.
[Causes of communication connection failure]
● Mismatched communication port (C
OM port)
● Disconnected communication cable
● Connection problem of communication cable connector
● Gateway unit side, PC side malfunction
● PC software double startup
may be possible causes.
"Alarm" screen