6.1 Parameter
B6-49
ME0384-4A
St
ar
tu
p
Se
ct
io
n
[Collision Detection Function (Parameter No. 168)]
No.
Name
Unit
Input range
Default initial value setting
168 Collision detection function
-
0 to 7
0
A function to generate a collision detection alarm and stop traveling (servo OFF) when the
actuator collides. Detects within the set range of the position zone.
For details, refer to "6.2 Various Functions / Collision detection function (page B6-72)".
Set
value
Content
Alarm level
0
No detection will be made (same even if 2, 4, 6 are set)
-
1
Detects within the set range of the position zone.
Operation cancel
level
3
(Note 1)
Detects within the set range of the position zone;
however,
no detection will be made in the following cases.
·First travel after pause release
·Travel from stop status within position zone range
5
Detects within the set range of the position zone.
Message level
7
(Note 1)
Detects within the set range of the position zone;
however,
no detection will be made in the following cases.
·First travel after pause release
·Travel from stop status within position zone range
Note 1: This setting can avoid occurrence of false detection due to current value during
acceleration.
Stepper motor specification only
Summary of Contents for Rcon
Page 12: ...ME0384 4A ...
Page 32: ...Actuator Coordinate System Intro 20 ME0384 4A ...
Page 42: ...1 3 General Specifications A1 9 ME0384 4A Specifications Section Chapter 1 RCON Overview ...
Page 45: ...ME0384 4A ...
Page 291: ...ME0384 4A ...
Page 323: ...ME0384 4A ...
Page 384: ...1 3 Startup Procedure B1 9 ME0384 4A Startup Section Chapter 1 Overview ...
Page 420: ...3 6 Precautions B3 15 ME0384 4A Startup Section Chapter 3 Absolute Reset ...
Page 588: ...6 2 Various Functions B6 81 ME0384 4A Startup Section ...
Page 837: ......
Page 838: ......