3.7 Address Configuration
A3-59
ME0384-4A
Spec
ifi
cat
ion
s
Sec
tion
Chapt
er 3
G
at
eway
Uni
t
(12) Stop mode
The servo can be turned OFF automatically at a fixed time after completion of positioning, for
power saving.
Time setting is performed with parameter No. 36 to 38 Automatic servo OFF delay time 1 to 3,
enabling three time options to be selected.
Servo motor specification and DC brush-less motor specification allow selection from 0 to 3.
Stepper motor specification allows selection from 0 to 7.
Set value
Operation after positioning complete
Selectable
specifications
0
Servo ON as is
All specifications
1
After a fixed time (parameter No. 36 set value)
AUTO servo OFF
All specifications
2
After a fixed time (parameter No. 37 set value)
AUTO servo OFF
All specifications
3
After a fixed time (parameter No. 38 set value)
AUTO servo OFF
All specifications
4
Full servo control
Stepper motor
specification
5
Fixed time (parameter No. 36 set value)
After full servo control, AUTO servo OFF
Stepper motor
specification
6
Fixed time (parameter No. 37 set value)
After full servo control, AUTO servo OFF
Stepper motor
specification
7
Fixed time (parameter No. 38 set value)
After full servo control, AUTO servo OFF
Stepper motor
specification
Caution
●
There is no holding torque during AUTO servo OFF. Take care with this setting, as the
actuator will move if external force is applied.
●
Do not use AUTO servo OFF when the next travel command is relative specifications
(pitch feed). Misalignment may occur.
●
Do not use AUTO servo OFF with push-motion operation. The pushing force will be
lost.
●
AUTO servo OFF does not function if operating in teaching mode with PC software.
Summary of Contents for Rcon
Page 12: ...ME0384 4A ...
Page 32: ...Actuator Coordinate System Intro 20 ME0384 4A ...
Page 42: ...1 3 General Specifications A1 9 ME0384 4A Specifications Section Chapter 1 RCON Overview ...
Page 45: ...ME0384 4A ...
Page 291: ...ME0384 4A ...
Page 323: ...ME0384 4A ...
Page 384: ...1 3 Startup Procedure B1 9 ME0384 4A Startup Section Chapter 1 Overview ...
Page 420: ...3 6 Precautions B3 15 ME0384 4A Startup Section Chapter 3 Absolute Reset ...
Page 588: ...6 2 Various Functions B6 81 ME0384 4A Startup Section ...
Page 837: ......
Page 838: ......