6.1 Parameter
B6-59
ME0384-4A
St
ar
tu
p
Se
ct
io
n
[Current control setting at stop (Parameter No. 6)]
No.
Name
Unit
Input range
Default initial value setting
6
Current control setting at
stop
-
Disabled : Powerful stop
Enabled : Energy-saving stop
Disabled
●
The control method for ELECYLINDER stop can be selected.
●
If [Disabled], a constant current value will be transmitted to the motor,
stopping it. This limits fine vibration when stopping, bringing the unit to
a complete stop.
●
If [Enabled], a current appropriate to the load will be transmitted to the motor,
stopping it. This limits the amount of power consumed while stopping.
●
If abnormal noise or vibration occurs during a gradual stop, setting to [Enabled]
may fix the issue. Moreover, setting to [Enabled] can also fix issues in which the
command position cannot quite be attained.
Caution
●
If [Disabled], even if a pulse deviation within
±
2 from the target position remains,
movement towards the target position will not continue.
●
If [Enabled], if a pulse deviation of
±
1 or more from the target position remains,
movement towards the target position will continue.
Elecylinder only
Summary of Contents for Rcon
Page 12: ...ME0384 4A ...
Page 32: ...Actuator Coordinate System Intro 20 ME0384 4A ...
Page 42: ...1 3 General Specifications A1 9 ME0384 4A Specifications Section Chapter 1 RCON Overview ...
Page 45: ...ME0384 4A ...
Page 291: ...ME0384 4A ...
Page 323: ...ME0384 4A ...
Page 384: ...1 3 Startup Procedure B1 9 ME0384 4A Startup Section Chapter 1 Overview ...
Page 420: ...3 6 Precautions B3 15 ME0384 4A Startup Section Chapter 3 Absolute Reset ...
Page 588: ...6 2 Various Functions B6 81 ME0384 4A Startup Section ...
Page 837: ......
Page 838: ......