3.7 Address Configuration
A3-69
ME0384-4A
Spec
ifi
cat
ion
s
Sec
tion
Chapt
er 3
G
at
eway
Uni
t
[I/O Signal List]
Direct numerical control mode
(ON = corresponding bit is "1", OFF = corresponding bit is "0")
Signal type
Bit
Signal
name
Content
Details
PLC
input
Status
signal
b4
SV
Operation ready
[ON: Operation ready (Servo ON)]
3.8 [5]
b3
ALM
Alarm
[ON: Alarm generated, OFF: No alarm]
3.8 [3]
b2
MOVE Traveling
[ON: Traveling, OFF: Stopped]
3.8
[6] [7]
b1
HEND
Home return complete
[ON: Maintaining home after home return
complete]
3.8 [6]
b0
PEND
Positioning complete
[ON
: After completion, stopped at servo ON,
OFF: For contactless push-motion, stopped
at servo OFF]
3.8
[5] ~ [7]