3.8 I/O Signals
A3-133
ME0384-4A
Spec
ifi
cat
ion
s
Sec
tion
Chapt
er 3 G
at
eway
Uni
t
[Pausing]
Deceleration to a stop occurs when the pause command signal STP is set to "1" (ON) during
actuator operation and the remaining travel distance is suspended. If the STP signal is set to "0"
(OFF) again, movement over the remaining travel distance is resumed.
If reset signal RES is set to "1" (ON) while paused, it is possible to cancel the remaining travel
distance. After that, the positioning complete signal PEND becomes "1" (ON) in about 1 ms
when cancellation of the pause command signal STP is recognized. (Detects the RES signal
and cancels it.)
Positioning start
(CSTR)
Spee
d
Decelerating
stop
Remaining travel
distance starts
Command position
Positioning complete
(PEND)
Completed position
Pause command
(STP)
Traveling
(MOVE)
Actuator travel
注意
Positioning start
(CSTR)
About 1 ms
Command position
Positioning complete
(PEND)
Completed position
Pause command
(STP)
Traveling
(MOVE)
Actuator travel
Reset
(RES)
Spee
d
Summary of Contents for Rcon
Page 12: ...ME0384 4A ...
Page 32: ...Actuator Coordinate System Intro 20 ME0384 4A ...
Page 42: ...1 3 General Specifications A1 9 ME0384 4A Specifications Section Chapter 1 RCON Overview ...
Page 45: ...ME0384 4A ...
Page 291: ...ME0384 4A ...
Page 323: ...ME0384 4A ...
Page 384: ...1 3 Startup Procedure B1 9 ME0384 4A Startup Section Chapter 1 Overview ...
Page 420: ...3 6 Precautions B3 15 ME0384 4A Startup Section Chapter 3 Absolute Reset ...
Page 588: ...6 2 Various Functions B6 81 ME0384 4A Startup Section ...
Page 837: ......
Page 838: ......