4.4 Address Configuration
B4-54
ME0384-4A
C
ha
pt
er
4
N
etw
or
k C
onf
igu
rat
ion
St
art
up
Se
ctio
n
■
DeviceNet overall address configuration example (positioner 2 mode + EC connection unit)
It is an example of having 12 axes in Positioner 2 Mode and one unit of the EC connection unit
getting connected.
PLC output
⇒
RCON
RCON
⇒
PLC input
Relative CH
*
High byte
Low byte
High byte
Low byte
0
Gateway control signal 0
Gateway status signal 0
1
Gateway control signal 1
Gateway status signal 1
8 words each
2
(Not available)
Power supply unit status signal 0
Fixed region
3
(Not available)
Power supply unit status signal 1
4
(Not available)
Power supply unit status signal 2
5
(Not available)
Power supply unit status signal 3
6
(Not available)
Power supply unit status signal 4
7
(Not available)
(Not available)
8
(Axis 0) Command position No.
(Axis 0) Completed position No.
2 words each
9
(Axis 0) Control signal
(Axis 0) Status signal
10
(Axis 1) Command position No.
(Axis 1) Completed position No.
11
(Axis 1) Control signal
(Axis 1) Status signal
12
(Axis 2) Command position No.
(Axis 2) Completed position No.
13
(Axis 2) Control signal
(Axis 2) Status signal
14
(Axis 3) Command position No.
(Axis 3) Completed position No.
15
(Axis 3) Control signal
(Axis 3) Status signal
16
(Axis 4) Command position No.
(Axis 4) Completed position No.
17
(Axis 4) Control signal
(Axis 4) Status signal
18
(Axis 5) Command position No.
(Axis 5) Completed position No.
19
(Axis 5) Control signal
(Axis 5) Status signal
20
(Axis 6) Command position No.
(Axis 6) Completed position No.
21
(Axis 6) Control signal
(Axis 6) Status signal
22
(Axis 7) Command position No.
(Axis 7) Completed position No.
23
(Axis 7) Control signal
(Axis 7) Status signal
24
(Axis 8) Command position No.
(Axis 8) Completed position No.
25
(Axis 8) Control signal
(Axis 8) Status signal
26
(Axis 9) Command position No.
(Axis 9) Completed position No.
27
(Axis 9) Control signal
(Axis 9) Status signal
28
(Axis 10) Command position No.
(Axis 10) Completed position No.
29
(Axis 10) Control signal
(Axis 10) Status signal
30
(Axis 11) Command position No.
(Axis 11) Completed position No.
31
(Axis 11) Control signal
(Axis 11) Status signal
32
(Axis 12 ~ Axis 15) Control signal
(Axis 12 ~ Axis 15) Status signal
1 word
*1
* Relative CH is the CH number relative to the gateway head CH
*1 The EC connection unit occupies domains and axis numbers for four axes (one word) even if not
all of four axes are connected.
The axes numbers for the EC connection unit should be assigned from the back of those in the
driver unit (RCON-PC/AC/DC/PCF/SC) and the SCON extension unit.
Summary of Contents for Rcon
Page 12: ...ME0384 4A ...
Page 32: ...Actuator Coordinate System Intro 20 ME0384 4A ...
Page 42: ...1 3 General Specifications A1 9 ME0384 4A Specifications Section Chapter 1 RCON Overview ...
Page 45: ...ME0384 4A ...
Page 291: ...ME0384 4A ...
Page 323: ...ME0384 4A ...
Page 384: ...1 3 Startup Procedure B1 9 ME0384 4A Startup Section Chapter 1 Overview ...
Page 420: ...3 6 Precautions B3 15 ME0384 4A Startup Section Chapter 3 Absolute Reset ...
Page 588: ...6 2 Various Functions B6 81 ME0384 4A Startup Section ...
Page 837: ......
Page 838: ......