[Installation and mounting]
Consider the size of the control panel, placement of the RCON controller, cooling and the like
when designing and manufacturing so that the ambient temperature is 0 to 55°C.
(If it has no fan unit, there is derating.)
When installing a simple absolute unit or SCON on the same control panel, design and
manufacture so that the ambient temperature is 0 to 40°C.
In particular, the performance may deteriorate when the temperature around the simple absolute
unit (battery) is too low or too high. Make sure that the temperature is as close to room
temperature as possible. (The recommended temperature is about 20°C.)
Item
Specifications
Item
Specifications
Installation direction Vertical mounting (exhaust side on top)
Ambient
operating
temperature
With fan unit
0 to 55°C
Installation method
DIN rail mounting
Without fan unit 0 to 55°C
(Note 1)
Installation conditions
See figure below
Ground
Class D grounding
Note 1: If there is no fan unit, derating is available.
100mm or more
10mm
or more
100m
m
or
m
or
e
50m
m o
r m
ore
* Simple absolute units can be installed in close contact with each other.
Ceiling
RCON
Simple
Absolute
Unit
Ceiling
10mm
or more
10mm
or more
Summary of Contents for Rcon
Page 12: ...ME0384 4A ...
Page 32: ...Actuator Coordinate System Intro 20 ME0384 4A ...
Page 42: ...1 3 General Specifications A1 9 ME0384 4A Specifications Section Chapter 1 RCON Overview ...
Page 45: ...ME0384 4A ...
Page 291: ...ME0384 4A ...
Page 323: ...ME0384 4A ...
Page 384: ...1 3 Startup Procedure B1 9 ME0384 4A Startup Section Chapter 1 Overview ...
Page 420: ...3 6 Precautions B3 15 ME0384 4A Startup Section Chapter 3 Absolute Reset ...
Page 588: ...6 2 Various Functions B6 81 ME0384 4A Startup Section ...
Page 837: ......
Page 838: ......