6.1 Parameter
B6-32
ME0384-4A
St
art
up
Se
ctio
n
[Rotary Axis Mode Select (Parameter No. 79)]
No.
Name
Unit
Input range
Default initial value setting
79 Rotary axis mode select
-
0: Normal mode
1: Index mode
In accordance with actuator
Sets rotary axis mode.
When parameter No. 78 "Axis Motion Type" is set to "1: Rotary axis," the present value
expression will be fixed to 0 ~ 359.99 by selecting index mode. Selection of the index mode will
enable shortcut control.
Set value
Content
0
Normal mode
1
Index mode
Index mode cannot be specified with an absolute specification actuator.
Caution
●
Push-motion operation is not available during index mode. Even if data is input for the
push-motion of position data, it will become invalid and normal travel will be executed.
Also, the positioning width will be the parameter positioning width initial value.
●
When changing the index mode setting to normal mode, the software limit value should
also be changed. If the software limit value is set to 0, a parameter data error will occur.
Value extended by 0.3mm to the outside of the effective stroke should be set.
●
In DD motor, switchover between the normal mode and the index mode cannot be
made in this parameter. Do not attempt to change the settings.
Summary of Contents for Rcon
Page 12: ...ME0384 4A ...
Page 32: ...Actuator Coordinate System Intro 20 ME0384 4A ...
Page 42: ...1 3 General Specifications A1 9 ME0384 4A Specifications Section Chapter 1 RCON Overview ...
Page 45: ...ME0384 4A ...
Page 291: ...ME0384 4A ...
Page 323: ...ME0384 4A ...
Page 384: ...1 3 Startup Procedure B1 9 ME0384 4A Startup Section Chapter 1 Overview ...
Page 420: ...3 6 Precautions B3 15 ME0384 4A Startup Section Chapter 3 Absolute Reset ...
Page 588: ...6 2 Various Functions B6 81 ME0384 4A Startup Section ...
Page 837: ......