3.7 Address Configuration
A3-52
ME0384-4A
Chapt
er 3 G
at
eway
Uni
t
Spec
ific
at
ion
s S
ec
tion
(7) Positioning width [mm]
Handling of set value differs between "positioning" and "push-motion operation".
[Positioning operation]
Defines how far before the target position the positioning complete signal should turn ON.
Even if the positioning complete turns ON, the actuator will continue to move to the target
position.
Increasing the positioning width value will speed up the next sequence operation, which will
shorten the tact time. Set the optimum value by looking at the overall balance of the equipment.
Tar
ge
t p
os
itio
n
Positioning width
Timing for when the positioning
complete signal turns ON