6.2 Various Functions
B6-77
ME0384-4A
St
ar
tu
p
Se
ct
io
n
[Setting of Power-saving Method]
Select from the following conditions, and set in "stop mode" of the position table, or with
Parameter No. 53 using a numerical value.
For AC servo motor specification and DC brush-less motor specification, select from 0 to 3.
For stepper motor specification, select from 0 to 7.
[Reference] Refer to "3.7 Address Configuration / Position table (page A3-48)".
Set
value
Operation after positioning complete
Selectable
specifications
0
Servo ON as is
All specifications
1
After a fixed time (parameter No. 36 set value) automatic servo OFF All specifications
2
After a fixed time (parameter No. 37 set value) automatic servo OFF All specifications
3
After a fixed time (parameter No. 38 set value) automatic servo OFF All specifications
4
Full servo control
Stepper motor
specification
(Excluding RCP6 Series)
5
After full servo control for a fixed time (parameter No. 36 set
value), automatic servo OFF
Stepper motor
specification
6
After full servo control for a fixed time (parameter No. 37 set
value), automatic servo OFF
Stepper motor
specification
7
After full servo control for a fixed time (parameter No. 38 set
value), automatic servo OFF
Stepper motor
specification
Caution
●
There is no holding torque during AUTO servo OFF. The actuator will move if external
force is applied. Take extra care when setting.
●
Do not use AUTO servo OFF when the next travel command is relative specifications
(pitch feed). Misalignment may occur.
●
Do not use AUTO servo OFF with push-motion operation. The pushing force will be lost.
●
AUTO servo OFF does not function if operating in teaching mode with PC software.
Summary of Contents for Rcon
Page 12: ...ME0384 4A ...
Page 32: ...Actuator Coordinate System Intro 20 ME0384 4A ...
Page 42: ...1 3 General Specifications A1 9 ME0384 4A Specifications Section Chapter 1 RCON Overview ...
Page 45: ...ME0384 4A ...
Page 291: ...ME0384 4A ...
Page 323: ...ME0384 4A ...
Page 384: ...1 3 Startup Procedure B1 9 ME0384 4A Startup Section Chapter 1 Overview ...
Page 420: ...3 6 Precautions B3 15 ME0384 4A Startup Section Chapter 3 Absolute Reset ...
Page 588: ...6 2 Various Functions B6 81 ME0384 4A Startup Section ...
Page 837: ......
Page 838: ......