2.4 Driver Unit/Simple Absolute Unit Alarm Causes and Countermeasures
C2-28
ME0384-4A
C
ha
pt
er
2
Troubl
es
hoot
ing
M
ai
nt
ena
nc
e
Sec
tion
Alarm
code
Alarm name
Causes/countermeasures
0F8
Non-volatile memory data
destruction
Cause: Abnormal data was detected by non-volatile memory check at
startup. (Failure of non-volatile memory)
Countermeasure: Contact IAI if this reoccurs even after turning ON the
power again.
0FA
CPU error
Cause: CPU is not operating normally.
1) CPU malfunction.
2) Malfunction caused by noise.
Countermeasure: Contact IAI if this reoccurs even after turning ON the
power again.
0FC
Logic error
(Controller part error)
Cause: RCON system interior is not working properly.
1) Malfunction due to noise or other causes.
2) Failure of a peripheral circuit component.
Countermeasure: Reboot the power.
If the error occurs again, check for presence of noise.
If a spare driver unit is available, replace it and try
again. A recurring error with the spare controller
suggests presence of noise.
Contact IAI if the cause cannot be determined.
300~
3FF
Teaching tool alarm
[Refer to teaching tool instruction manual]
Summary of Contents for Rcon
Page 12: ...ME0384 4A ...
Page 32: ...Actuator Coordinate System Intro 20 ME0384 4A ...
Page 42: ...1 3 General Specifications A1 9 ME0384 4A Specifications Section Chapter 1 RCON Overview ...
Page 45: ...ME0384 4A ...
Page 291: ...ME0384 4A ...
Page 323: ...ME0384 4A ...
Page 384: ...1 3 Startup Procedure B1 9 ME0384 4A Startup Section Chapter 1 Overview ...
Page 420: ...3 6 Precautions B3 15 ME0384 4A Startup Section Chapter 3 Absolute Reset ...
Page 588: ...6 2 Various Functions B6 81 ME0384 4A Startup Section ...
Page 837: ......
Page 838: ......