2.4 Driver Unit/Simple Absolute Unit Alarm Causes and Countermeasures
C2-20
ME0384-4A
C
ha
pt
er
2
Troubl
es
hoot
ing
M
ai
nt
ena
nc
e
Sec
tion
(3) Cold start level
Alarm
code
Alarm name
Causes/countermeasures
09B
P
Driver
limited
Internal communication
error
Cause:
There was an internal communication error occurred between
the gateway unit and driver unit.
1) Installation error or contact error on the link connector
between gateway unit and driver unit.
2) Influence of noise generated by a peripheral device
3) Malfunction of gateway unit or driver unit
Countermeasure: 1) Disconnect and then connect the link between the gateway
unit and driver unit to see if the alarm gets generated.
If it
does, check (2) and (3).
2) Shut down the power on peripheral devices and operate
only with the controller and actuators to see if this alarm
gets generated again.
If the alarm does not get generated,
there is a concern of influence of noise from a peripheral
device.
Revise the noise prevention on peripheral devices
such as grounding and electrostatic shielding.
3) Replace the gateway unit or driver unit.
The driver unit
number to be replaced can be checked in the table below
based on the detail address displayed in the alarm list.
Detail
address
driver unit
number
Detail
address
driver unit
number
0001
0
0801
8
0101
1
0901
9
0201
2
0A01
10
0301
3
0B01
11
0401
4
0C01
12
0501
5
0D01
13
0601
6
0E01
14
0701
7
0F01
15
09C
P, A
Driver
limited
Servo ON command after
encoder FRAM read/write
Cause:
After inputting a memo using the user memo edit function (a
function that enables to save memos on the actuator side),
servo was turned on without executing RCON system reboot
or reboot of the power supply.
Countermeasure: Reboot the RCON system or the power supply.
0A1
Parameter data error
Cause: Data input range of parameter domain is not appropriate.
(Example 1) This error occurs when the magnitude correlation
is obviously inappropriate, such as when 300 mm
was incorrectly input as the value of the software
limit negative side while the value of the software
limit positive side was 200.3 mm.
(Example 2) For rotary axis, this error is generated when the
index mode is changed to the normal mode and
the software limit negative side is 0. Set the
software limit negative side to the -0.3 mm value
added to the outside of the effective stroke.
[Refer to Startup Section Chapter 6, 6.1
Parameter (page B6-6)]
(Example 3) It occurs when the initial positioning band value [refer to
Startup Section Chapter 6, 6.1 Parameter (page
B6-12)] is smaller than the minimum positioning band
width when an actuator in RCP2, RCP3, RCP4 or
RCP5 Series is connected. Set the initial positioning
band value to the minimum positioning band width
(lead length ÷ number of encoder pulse: 800) × 3 or
more.
Countermeasure: Change to an appropriate value.
Summary of Contents for Rcon
Page 12: ...ME0384 4A ...
Page 32: ...Actuator Coordinate System Intro 20 ME0384 4A ...
Page 42: ...1 3 General Specifications A1 9 ME0384 4A Specifications Section Chapter 1 RCON Overview ...
Page 45: ...ME0384 4A ...
Page 291: ...ME0384 4A ...
Page 323: ...ME0384 4A ...
Page 384: ...1 3 Startup Procedure B1 9 ME0384 4A Startup Section Chapter 1 Overview ...
Page 420: ...3 6 Precautions B3 15 ME0384 4A Startup Section Chapter 3 Absolute Reset ...
Page 588: ...6 2 Various Functions B6 81 ME0384 4A Startup Section ...
Page 837: ......
Page 838: ......