SJ700
2
Inverter
Appendix B
B–7
Commands –
02 and 12
The 02 command sets the logic state (ON or OFF) of the intelligent input terminals.
The frame format of command 02 follows the
timing diagram and specification table.
The 16-byte data string is specified in the following tables:
Element
Description
Size
Value
STX
Control code (STart of TeXt)
1 byte
STX (0x02)
Node
Node (station) address of inverter 2 bytes
01 to 32, and FF (broadcast to all)
Command
Transmission command
2 bytes
02 or 12
Data
Transmission data
16 bytes (see tables below)
BCC
Block check sum code
2 bytes
Exclusive OR of Node,
Command, and Data
[CR]
Control code (carriage return)
1 byte
[CR] (0x0D)
STX Node
Command
Data
BCC [CR]
Frame format
Data (Hex)
02 Command Description
Data (Hex)
02 CommandDescription
0000000000000001
[FW] Forward command
0000000100000000
[SF1] Multi-speed bit-level
0000000000000002
[RV] Reverse command
0000000200000000
[SF2] Multi-speed bit-level
0000000000000004
[CF1] Multi-speed 1
0000000400000000
[SF3] Multi-speed bit-level
0000000000000008
[CF2] Multi-speed 2
0000000800000000
[SF4] Multi-speed bit-level
0000000000000010
[CF3] Multi-speed 3
0000001000000000
[SF5] Multi-speed bit-level
0000000000000020
[CF4] Multi-speed 4
0000002000000000
[SF6] Multi-speed bit-level
0000000000000040
[JG] Jog operation
0000004000000000
[SF7] Multi-speed bit-level
0000000000000080
[DB] Dynamic braking
0000008000000000
[OLR] Overload restriction setting
0000000000000100
[SET] set 2nd motor
0000010000000000
[TL] Torque limit
0000000000000200
[2CH] 2-stage adjustable speed
0000020000000000
[TRQ1] Torque limit select 1
0000000000000400
—
0000040000000000
[TRQ2] Torque limit select 2
0000000000000800
[FRS] Free-run stop
0000080000000000
[PPI P/PI] inverter mode select
0000000000001000
[EXP] External trip
0000100000000000
[BOK] Brake confirmation
0000000000002000
[USP] Unattended start protection
0000200000000000
[ORT] Orientation (home) command
0000000000004000
[CS] Commercial power change
0000400000000000
[LAC] Linear Accel/decel Cancel
0000000000008000
[SFT] Software lock
0000800000000000
[PCLR] Position error clear
0000000000010000
[AT] analog input voltage/current
0001000000000000
[STAT] Pulse train input enable
0000000000020000
[SET3] Set 3rd motor
0002000000000000
—
0000000000040000
[RS] Reset
0004000000000000
[ADD] Trigger for frequency addition
0000000000080000
—
0008000000000000
[F-TM] Forcible terminal operation
0000000000100000
[STA] 3-wire Start
0010000000000000
[ATR] Permission of torque command
0000000000200000
[STP] 3-wire Hold
0020000000000000
[KHC] Cumulative power clearance
0000000000400000
[F/R] 3-wire FWD/REV
0040000000000000
[SON] Servo ON
0000000000800000
[PID] PID enable
0080000000000000
[FOC] Forcing
0000000001000000
[PIDC] PID integrator reset
0100000000000000
[MI1] General-purpose input 1
0000000002000000
—
0200000000000000
[MI2] General-purpose input 2