ModBus Data Listing
Append
ix
B
B–54
B313
— Electronic thermal charac-
teristic, 3rd motor
R/W
00 . Reduced torque
01 . Constant torque
02 . Free-setting
330Dh
13069
0, 1, 2
—
—
(Reserved)
—
—
330Eh
to
3506h
13070
to
13574
—
—
B015
— Free setting, electronic
thermal frequency (1)
R/W
Data point coordinates for Hz
axis (horizontal) in the free-form
curve
1310h
04880
0 to 400
1 Hz
B016
— Free setting, electronic
thermal current (1)
R/W
Data point coordinates for
Ampere axis (vertical) in the
free-form curve
1311h
04881
0 to rated
current
0.1 A
B017
— Free setting, electronic
thermal frequency (2)
R/W
Data point coordinates for Hz
axis (horizontal) in the free-form
curve
1312h
04882
0 to 400
1 Hz
B018
— Free setting, electronic
thermal current (2)
R/W
Data point coordinates for
Ampere axis (vertical) in the
free-form curve
1313h
04883
0 to rated
current
0.1 A
B019
— Free setting, electronic
thermal frequency (3)
R/W
Data point coordinates for Hz
axis (horizontal) in the free-form
curve
1314h
04884
0 to 400
1 Hz
B020
— Free setting, electronic
thermal current (3)
R/W
Data point coordinates for
Ampere axis (vertical) in the
free-form curve
1315h
04885
0 to rated
current
0.1 A
B021
— Overload restriction opera-
tion mode
R/W
00 . Disable
01 . Enable for acceleration
and constant speed
02 . Enable for constant
speed only
03 . Enable for accel, decel,
and constant speed
1316h
04886
0 to 3
—
B022
— Overload restriction setting
R/W
(0.20 x rated current) to (1.80 x
rated current) (A)
1317h
04887
200 to
2000
0.1 %
B023
— Deceleration rate at
overload restriction
R/W
0.10 to 30.00 (seconds)
1318h
04888
10 to 3000
0.1 sec.
B024
— Overload restriction opera-
tion mode (2)
R/W
00 . Disable
01 . Enable for acceleration
and constant speed
02 . Enable for constant
speed only
03 . Enable for accel, decel,
and constant speed
1319h
04889
0 to 3
—
B025
— Overload restriction setting
(2)
R/W
(0.20 x rated current) to (1.80 x
rated current) (A)
131Ah
04890
200 to
2000
0.1 %
B026
— Deceleration rate at
overload restriction (2)
R/W
0.10 to 30.00 (seconds)
131Bh
04891
1 to 3000
0.01 sec.
B027
— Overcurrent suppression
enable
R/W
00 . Disable
01 . Enable
131Ch
04892
0, 1
—
B028
— Current limit for active
frequency-matching restart
R/W
(0.20 x rated current) to (1.80 x
rated current) (A)
131Dh
04893
200 to
2000
0.1 %
Holding Registers, “B” Group Fine Tuning Functions
Func. Code
Name
R/W
Description
Network Data
Register
Range
Res.
hex
dec.