SJ700
2
Inverter
Configur
ing Dr
iv
e
P
a
ra
met
e
rs
3–67
Func.
Code
Name/
Description
Keypad
Range and Settings
Defaults
Run
Mode
Edit
Lo Hi
SRW
OPE
FEF2
FE2
(EU)
FUF2
FU2
(USA)
FF2
F2
(Jpn)
H005
Motor speed constant, 1st motor
0.001 to 9.999, 10.00 to 80.00 (10.000 to
80.000)
1.590
1.590
1.590
✔ ✔
Motor proportional gain constant, factory set
H205
Motor speed constant, 2nd motor
0.001 to 9.999, 10.00 to 80.00 (10.000 to
80.000)
1.590
1.590
1.590
✔ ✔
Motor proportional gain constant, factory set
H006
Motor stabilization constant, 1st motor
0. to 255. (factory set)
100.
100.
100.
✔ ✔
H206
Motor stabilization constant, 2nd motor
0. to 255. (factory set)
100.
100.
100.
✔ ✔
H306
Motor stabilization constant, 3rd motor
0. to 255. (factory set)
100.
100.
100.
✔ ✔
H020
Motor constant R1, 1st motor
0.001 to 9.999, 10.00 to 65.53 (Ohms)
According to inverter
rating
✘ ✘
H220
Motor constant R1, 2nd motor
0.001 to 9.999, 10.00 to 65.53 (Ohms)
✘ ✘
H021
Motor constant R2, 1st motor
0.001 to 9.999, 10.00 to 65.53 (Ohms)
✘ ✘
H221
Motor constant R2, 2nd motor
0.001 to 9.999, 10.00 to 65.53 (Ohms)
✘ ✘
H022
Motor constant L, 1st motor
0.01 to 99.99, 100.0 - 655.3 (mH)
According to inverter
rating
✘ ✘
H222
Motor constant L, 2nd motor
0.01 to 99.99, 100.0 - 655.3 (mH)
✘ ✘
H023
Motor constant I
0
, 1st motor
0.01 to 99.99, 100.0 - 655.3 (A)
✘ ✘
H223
Motor constant I
0
, 2nd motor
0.01 to 99.99, 100.0 - 655.3 (A)
✘ ✘
H024
Motor Constant J, 1st motor
0.001 to 9.999, 10.00 to 99.99, 100.0 to
999.9, 1000 to 9999. (ratio, unit-less)
According to inverter
rating
✘ ✘
H224
Motor constant J, 2nd motor
0.001 to 9.999, 10.00 to 99.99, 100.0 to
999.9, 1000 to 9999. (ratio, unit-less)
✘ ✘
H030
Auto-tuned motor constant R1, 1st motor
0.001 to 9.999, 10.00 to 65.53 (Ohms)
According to inverter
rating
✘ ✘
H230
Auto-tuned motor constant R1, 2nd motor
0.001 to 9.999, 10.00 to 65.53 (Ohms)
✘ ✘
H031
Auto-tuned motor constant R2, 1st motor
0.001 to 9.999, 10.00 to 65.53 (Ohms)
According to inverter
rating
✘ ✘
H231
Auto-tuned motor constant R2, 2nd motor
0.001 to 9.999, 10.00 to 65.53 (Ohms)
✘ ✘
H032
Auto-tuned motor constant L, 1st motor
0.01 to 99.99, 100.0 to 655.3 (mH)
According to inverter
rating
✘ ✘
H232
Auto-tuned motor constant L, 2nd motor
0.01 to 99.99, 100.0 to 655.3 (mH)
✘ ✘
H033
Auto-tuned motor constant I
0
, 1st motor
0.01 to 99.99, 100.0 to 655.3 (mH)
According to inverter
rating
✘ ✘
H233
Auto-tuned motor constant I
0
, 2nd motor
0.01 to 99.99, 100.0 to 655.3 (mH)
✘ ✘
H034
Auto-tuned motor constant J, 1st motor
0.001 to 9.999, 10.00 to 99.99, 100.0 to
999.9, 1000 to 9999. (ratio, unit-less)
According to inverter
rating
✘ ✘
H234
Auto constant J, 2nd motor
0.001 to 9.999, 10.00 to 99.99, 100.0 to
999.9, 1000 to 9999. (ratio, unit-less)
✘ ✘
H050
PI proportional gain for 1st motor
0.0 to 999.9, 1000.
100.0
100.0
100.0
✔ ✔
H250
PI proportional gain for 2nd motor
0.0 to 999.9, 1000.
100.0
100.0
100.0
✔ ✔
H051
PI integral gain for 1st motor
0.0 to 999.9, 1000.
100.0
100.0
100.0
✔ ✔
H251
PI integral gain for 2nd motor
0.0 to 999.9, 1000.
100.0
100.0
100.0
✔ ✔
H052
P proportional gain setting for 1st motor
0.01 to 10.00
1.00
1.00
1.00
✔ ✔
H252
P proportional gain setting for 2nd motor
0.01 to 10.00
1.00
1.00
1.00
✔ ✔
H060
0Hz SLV limit for 1st motor
0.0 to 100.0
100.
100.
100.
✔ ✔