“U” Group: User-selectable Menu Functions
The user-selectable menu functions allow you to configure (select) any twelve of the other
functions in the inverter and place them together in a convenient list. This feature provides
quick access for the most-used functions needed for your application. Each U Group function
can serve as a pointer to any of the other parameters. You do
not
have to use the Store key to
retain each association; just scroll to the desired standard parameter for each U Group function
and leave it. The setting can point to a monitor-only parameter (such as D001), or point to
editable parameters (such as A001). In the case of pointing to an editable functions, you use the
Up/Down keys to change the value and the Store key to accept the change into memory—the
same procedure as a normal parameter edit.
TIP:
Function B037 selects which parameter groups are displayed. If you want to limit the
displayed parameters to
only
the U Group functions, set B037=02.
Func.
Code
Name/
Description
Range and Settings
Defaults
Run
Mode
Edit
Lo Hi
FEF2
FE2
(EU)
FUF2
FU2
(USA)
FF2
F2
(Jpn)
U001
User function 1
“no” (disabled), or any of the
functions D001 to P049
no
no
no
✘ ✔
U002
User function 2
no
no
no
✘ ✔
U003
User function 3
no
no
no
✘ ✔
U004
User function 4
no
no
no
✘ ✔
U005
User function 5
no
no
no
✘ ✔
U006
User function 6
no
no
no
✘ ✔
U007
User function 7
no
no
no
✘ ✔
U008
User function 8
no
no
no
✘ ✔
U009
User function 9
no
no
no
✘ ✔
U010
User function 10
no
no
no
✘ ✔
U011
User function 11
no
no
no
✘ ✔
U012
User function 12
no
no
no
✘ ✔