SJ700
2
Inverter
Appendix B
B–37
D016
H Cumulative operation RUN
time monitor
R
Displays total time the inverter
has been in RUN mode in hours.
Range is 0 to 9999 / 1000 to
9999/ 100 to 999 (10,000 to
99,900) hrs.
1015h
04117
0 to 999900
0.1
D016
L
R
1016h
04118
D017
(high)
H Cumulative power-on time
monitor
R
Displays total time the inverter
has had input power (ON) in
hours. Range is:
0 to 9999 / 100.0 to 999.9 /
1000 to 9999 / 100 to 999 hrs.
1017h
04119
0 to 999900
1 hour
D017
(low)
L
R
1018h
04120
D018
— Heat sink temperature
monitor
R
Displays the temperature of the
inverter’s heat sink
1019h
04121
-200 to 2000
0.1 °C
D019
— Motor temperature monitor
R
Displays motor internal tempera-
ture (requires an NTC thermistor
installed in the motor and
connected to [TH] and [CM1])
101Ah
04122
-200 to 2000
0.1 °C
—
(Reserved)
—
—
101Bh
04123
—
—
—
(Reserved)
—
—
101Ch
04124
—
—
D022
— Component life monitor
R
Displays estimated life status of
DC bus capacitors and cooling
fans
101Dh
04125
bit 0... capa-
citors
bit 1...fans
1 bit
—
(Reserved)
—
—
101Eh
to
1025h
04126
to
04133
—
—
D025
H User monitor 0
R
Displays state of internal EZ
Sequence register User Monitor
0
102Eh
04142
-2147483647
to
2147483647
1
D025
L
R
102Fh
04143
D026
H User monitor 1
R
Displays state of internal EZ
Sequence register User Monitor
2
1030h
04144
-2147483647
to
2147483647
1
D026
L
R
1031h
04145
D027
H User monitor 2
R
Displays state of internal EZ
Sequence register User Monitor
2
1032h
04146
-2147483647
to
2147483647
1
D027
L
R
1033h
04147
D028
H Pulse counter
R/W
Displays accumulated pulse
count of [PCNT] intelligent input
terminal (option code 74)
1034h
04148
0 to
2147483647
1
D028
L
R/W
1035h
04149
D029
H Position setting monitor
R
Displays absolute position
command for motor shaft in
absolute position control mode
1036h
04150
-2147483647
to
2147483647
1
D029
L
R
1037h
04151
D030
H Position feedback monitor
R
Displays absolute position of
motor shaft when in absolute
position control mode
1038h
04152
-2147483647
to
2147483647
1
D030
L
R
1039h
04153
D080
— Trip counter
R
Number of trip events
0011h
00017
0 to 65535
1 trip
event
Holding Registers, “D” Group Monitor Functions
Func. Code
Name
R/W
Description
Network Data
Register
Range
Res.
hex
dec.