Parameter Settings for Keypad Entry
Appendix C
C–12
C071
Communication speed selection
04
04
04
C072
Node allocation
1.
1.
1.
C073
Communication data length selection
7
7
7
C074
Communication parity selection
00
00
00
C075
Communication stop bit selection
1
1
1
C076
Action upon communication error selection
02
02
02
C077
Communication timeout before trip
0.00
0.00
0.00
C078
Communication wait time
0.
0.
0.
C079
Communication protocol select
00
00
00
C081
[O] input span calibration
Factory set
Factory set
Factory set
C082
[OI] input span calibration
Factory set
Factory set
Factory set
C083
[O2] input span calibration
Factory set
Factory set
Factory set
C085
Thermistor input tuning
105.0
105.0
105.0
C086
[AM] terminal offset tuning
0.0
0.0
0.0
C087
[AMI] terminal meter tuning
80.
80.
80.
C088
[AMI] terminal offset tuning
Factory set
Factory set
Factory set
C091
Debug mode enable
00
00
00
Do not edit
C101
Up/Down memory mode selection
00
00
00
C102
Reset mode selection
00
00
00
C103
Restart mode after reset
00
00
00
C105
FM gain adjustment
100.
100.
100.
C106
AM gain adjustment
100.
100.
100.
C107
AMI gain adjustment
100.
100.
100.
C109
AM bias adjustment
0.
0.
0.
C110
AMI bias adjustment
20.
20.
20.
C111
Overload setting (2)
Rated current for each inverter model
C121
[O] input zero calibration
Factory set
C122
[OI] input zero calibration
Factory set
C123
[O2] input zero calibration
Factory set
C130
Terminal [11] ON-delay time
0.0
0.0
0.0
C131
Terminal [11] OFF-delay time
0.0
0.0
0.0
C132
Terminal [12] ON-delay time
0.0
0.0
0.0
C133
Terminal [12] OFF-delay time
0.0
0.0
0.0
C134
Terminal [13] ON-delay time
0.0
0.0
0.0
C135
Terminal [13] OFF-delay time
0.0
0.0
0.0
C136
Terminal [14] ON-delay time
0.0
0.0
0.0
“C” Group Parameters
Default Setting
User
Setting
Func.
Code
Name
FEF2, FE2
(Europe)
FU2, FU2
(U.S.A.)
FF2, F2
(Japan)