SJ700
2
Inverter
Appendix B
B–69
Use the codes in the table below to return parameters for H003 and H203 (motor capacity
selection).
H073
— Gain switching time
R/W
0. to 999. (milliseconds)
1554h
05460
0 to 9999
1 msec.
—
(Reserved)
—
—
1555h
to
1600h
05461
to
05632
—
—
Holding Registers, “H” Group Motor Constants Functions
Func. Code
Name
R/W
Description
Network Data
Register
Range
Res.
hex
dec.
Code Data
00
01
02
03
04
05
06
07
08
09
10
Japan or U.S.A. mode
(B085 = 00 or 02)
0.2 kW
—
0.4
—
0.75
—
1.5
2.2
—
3.7
—
EU mode (B085=01)
0.2 kW
0.37
—
0.55
0.75
1.1
1.5
2.2
3.0
—
4.0
Code Data
11
12
13
14
15
16
17
18
19
20
21
Japan or U.S.A. mode
(B085 = 00 or 02)
5.5 kW
7.5
11
15
18.5
22
30
37
45
55
75
EU mode (B085=01)
5.5 kW
7.5
11
15
18.5
22
30
37
45
55
75
Code Data
22
23
24
25
26
27
28
29
30
31
32
Japan or U.S.A. mode
(B085 = 00 or 02)
90 kW
110
132
150
160
185
200
220
250
280
300
EU mode (B085=01)
90 kW
110
132
150
160
185
300
220
250
280
300
Code Data
33
34
35
36
Japan or U.S.A. mode
(B085 = 00 or 02)
315 kW
340
355
400
EU mode (B085=01)
315 kW
340
355
400