ModBus Data Listing
Append
ix
B
B–56
B042
— Torque limit (2) (reverse-
regenerating in 4-quadrant
mode)
R/W
0. to 200. (%), no (disable torque
limit)
132Ch
04908
0 to 200,
255= (no)
1 %
B043
— Torque limit (3) (reverse-
driving in 4-quadrant
mode)
R/W
0. to 200. (%), no (disable torque
limit)
132Dh
04909
0 to 200,
255= (no)
1 %
B044
— Torque limit (4) (forward-
regenerating in 4-quadrant
mode)
R/W
0. to 200. (%), no (disable torque
limit)
132Eh
04910
0 to 200,
255= (no)
1 %
B045
— Torque limit LADSTOP
enable
R/W
00 . Disable
01 . Enable
132Fh
04911
0, 1
—
B046
— Reverse Run protection
enable
R/W
00 . Disable
01 . Enable
1330h
04912
0, 1
—
—
(Reserved)
—
—
1331h
to
1333h
04913
to
04915
—
—
B050
— Controller deceleration and
stop on power loss
R/W
00 . Disable
01 . Constant decel to stop
02 . Constant DC voltage
control with resume
03 . Constant DC voltage
control
1334h
04916
0 to 3
—
B051
— DC bus voltage trigger
level during power loss
R/W
Sets trigger for controlled decel-
eration and stop on power loss
function
1335h
04917
0 to 10000
0.1 V
B052
— Over-voltage threshold
during power loss
R/W
Sets over-voltage threshold for
controlled deceleration function
1336h
04918
0 to 10000
0.1 V
B053
H Deceleration time setting
during power loss
R/W
0.01 to 99.99, 100.0 to 999.9,
1000 to 3600 (seconds)
1337h
04919
0 to
360000
0.01 sec.
B053
L
R/W
1338h
04920
B054
— Initial output frequency
decrease during power loss
R/W
Sets the initial decrease in output
frequency upon power loss
1339h
04921
0 to 1000
0.01 Hz
B055
— Proportional gain setting
for non-stop operation at
power loss
R/W
0.00 to 2.55
133Ah
04922
0 to 255
0.01
B056
— Integral time setting for
non-stop operation at
power loss
R/W
0.0 to 9.999, 10.00 to 65.55
133Bh
04923
0 to 65535
0.001
sec.
—
(Reserved)
—
—
133Ch
to
133Eh
04924
to
04926
—
—
B060
— [O] input max. limit level
of window comparator
R/W
0. to 100. (%)
Lower limit = B061 + B062 / 2
133Fh
04927
0 to 100
1 %
B061
— [O] input min. limit level
of window comparator
R/W
0. to 100. (%)
Lower limit = B060 – B062 / 2
1340h
04928
0 to 100
1 %
B062
— [O] input hysteresis width
of window comparator
R/W
0. to 10. (%)
Lower limit = B061 – B062 / 2
1341h
04929
0 to 10
1 %
B063
— [OI] input max. limit level
of window comparator
R/W
0. to 100. (%)
Lower limit = B064 + B066 / 2
1342h
04930
0 to 100
1 %
Holding Registers, “B” Group Fine Tuning Functions
Func. Code
Name
R/W
Description
Network Data
Register
Range
Res.
hex
dec.