SJ700
2
Inverter
Appendix C
C–7
Fine Tuning
Functions
“B” Group Parameters
Default Setting
User
Setting
Func.
Code
Name
FEF2, FE2
(Europe)
FU2, FU2
(U.S.A.)
FF2, F2
(Japan)
B001
Selection of restart mode
00
00
00
B002
Allowable under-voltage power failure time
1.0
1.0
1.0
B003
Retry wait time before motor restart
1.0
1.0
1.0
B004
Instantaneous power failure / under-voltage trip
alarm enable
00
00
00
B005
Number of restarts on power failure / under-voltage
trip events
00
00
00
B006
Phase loss detection enable
00
00
00
B007
Restart frequency threshold
0.00
0.00
0.00
B008
Retry after trip select
00
00
00
B009
Retry after undervoltage select
00
00
00
B010
Retry count select after overvoltage or overcurrent
3
3
3
B011
Retry wait time after trip
1.0
1.0
1.0
B012
Electronic thermal setting (calculated within the
inverter from current output)
Rated current for each inverter
B212
Electronic thermal setting (calculated within the
inverter from current output), 2nd motor
Rated current for each inverter
B312
Electronic thermal setting (calculated within the
inverter from current output), 3rd motor
Rated current for each inverter
B013
Electronic thermal characteristic
01
01
00
B213
Electronic thermal characteristic, 2nd motor
01
01
00
B313
Electronic thermal characteristic, 3rd motor
01
01
00
B015
Free setting, electronic thermal frequency (1)
0.
0.
0.
B016
Free setting, electronic thermal current (1)
0.0
0.0
0.0
B017
Free setting, electronic thermal frequency (2)
0.
0.
0.
B018
Free setting, electronic thermal current (2)
0.0
0.0
0.0
B019
Free setting, electronic thermal frequency (3)
0.
0.
0.
B020
Free setting, electronic thermal current (3)
0.0
0.0
0.0
B021
Overload restriction operation mode
01
01
01
B022
Overload restriction setting
Rated current x 1.50
B023
Deceleration rate at overload restriction
1.0
1.0
1.0
B024
Overload restriction operation mode (2)
01
01
01
B025
Overload restriction setting (2)
Rated current x 1.50
B026
Deceleration rate at overload restriction (2)
1.00
1.00
1.00
B027
Overcurrent suppression enable
01
01
01
B028
Current limit for active frequency-matching restart
Rated current x 1.0