Output
signal
Intelligent Output terminals
(assign six functions to five
open collector outputs and
one relay NO-NC contact)
RUN (run signal), FA1 (Frequency arrival type 1 – constant speed), FA2 (Frequency
arrival type 2 – over-frequency), OL (overload advance notice signal 1), OD (Output
deviation for PID control), AL (alarm signal), FA3 (Frequency arrival type 3 – at-
frequency), OTQ (over-torque signal), IP (Instantaneous power failure signal), UV
(Under-voltage signal), TRQ (In torque limit), RNT (Run time over), ONT (Power-ON
time over), THM (thermal alarm), BRK (Brake release signal), BER (Brake error
signal), ZS (Zero speed detect), DSE (speed deviation maximum), POK (Positioning
completion), FA4 (Frequency arrival type 4 – over-frequency 2), FA5 (Frequency arrival
type 5 – at-frequency 2), OL2 (Overload notice advance signal 2), FBV (PID feedback
comparison), NDc (communication line disconnection), LOG1 (logical operation result
1), LOG2 (logical operation result 2), LOG3 (logical operation result 3), LOG4 (logical
operation result 4), LOG5 (logical operation result 5), LOG6 (logical operation result
6), WAC (capacitor life warning), WAF (cooling fan speed drop), FR (starting contact
signal), OHF (heat sink overheat warning), LOC (low-current indication signal), MO1
(general-purpose output 1), MO2 (general-purpose output 2), MO3 (general-purpose
output 3), MO4 (general-purpose output 4), MO5 (general-purpose output 5), MO6
(general-purpose output 6), IRDY (inverter ready), FWR (forward rotation signal), RVR
(reverse rotation signal), MJA (major failure signal), Terminals 11-13 or 11-14 automat-
ically configured as AC0-AC2 or AC0-AC3 per alarm code output selection
Intelligent monitor output
terminals
Analog voltage monitor, analog current monitor (8-bit resolution), and PWM output, on
terminals [AM], [AMI], [FM]
Display monitor
Output frequency, output current, motor torque, scaled value of output frequency, trip
history, I/O terminal condition, electrical power and other parameters
Other user-settable parameters
V/F free-setting (up to 7 points), freq. upper/lower limit, freq. jump, accel/decel curve
selection, manual torque boost value and freq. adjustment, energy saving operation,
analog meter tuning, start frequency, carrier frequency, electronic thermal protection
level, external frequency output zero/span reference, external frequency input bias start/
end, analog input selection, retry after trip, restart after instantaneous power failure,
various signal outputs, reduced voltage start, overload restriction, default value setting
(US, Europe, Japan), automatic deceleration at power failure, AVR function, fuzzy
accel/decel, auto-tuning (on-line/off-line), high-torque multi-motor operation (sensor-
less vector control of two motors by one inverter)
Protective functions
Over-current, overload, braking resistor overload, over voltage, EEPROM error, under-
voltage error, CT (current transformer) error, CPU error, external trip, USP error,
ground fault, input over voltage, instantaneous power failure, expansion card 1 error,
expansion card 2 error, inverter thermal trip, phase failure detection, IGBT error, therm-
istor error
Environ-
ment
Temperature (*9)
Operating (ambient): -10 to 50
°
C / Storage: -20 to 65
°
C
Humidity
20 to 90% relative humidity (non-condensing)
Vibration *10
Models SJ700–004xxx to 220xxx: 5.9 m/s
2
(0.6G), 10 to 55 Hz
Models SJ700–300xx to 1500xxx: 2.94 m/s
2
(0.3G), 10 to 55 Hz
Models SJ700–3150xx to 4000xxx: 1.96 m/s
2
(0.2G), 10 to 55 Hz
Location
Altitude 1,000 m or less, indoors (no corrosive gasses or dust)
Coating color
Gray
Accessories
Feedback expansion card
SJ-FB (vector control loop speed sensor)
Digital input exp. card
SJ-DG (4-digit BCD / 16-bit binary)
DeviceNet expansion card
Option to support the open-network DeviceNet function
LonWorks expansion card
Option to support the open-network LonWorks function
Profibus-DP option
Option to support the open-network Profibus-DP function
Other optional accessories
EMI filter, AC reactor, DC reactor, radio noise filter, braking resistors, braking units,
LCR filter, communication cables
Operator input devices
OPE–SRE (4-digit LED with potentiometer) / OPE–S (4-digit LED w/o potentiometer),
Optional: OPE-SR (4-digit LED with potentiometer, Japanese/English overlay),
SRW–0EX Multilingual operator with copy function (English, Spanish, French,
German, Italian, and Portuguese)
Item
General Specifications