COMMERCIAL ON-GRID 
SOLAR INVERTER

  

User Manual

Specifications are subject 
to change without notice. 

r25

Tel: 

(86)20 66608588     

Fax: 

(86)20 66608589     

Web:

 www.saj-electric.com

Add: 

SAJ Innovation Park,No.9, Lizhishan Road,Science City, 

Guangzhou High-tech Zone , Guangdong, P.R.China

GUANGZHOU SANJING
ELECTRIC CO.,LTD

C6-75K

-T6         /    

C6-100K

-T9         /    

C6-110K

-T12        /    

C6-125K

-T12

C6-50K-T6

-LV

    /    

C6-60K-T9

-LV

    /    

C6-70K-T12

-LV   

V1.0

广州三晶电气股份有限公司

2023-02-01

技术资料专用章

Summary of Contents for C6 Series

Page 1: ...86 20 66608588 Fax 86 20 66608589 Web www saj electric com Add SAJ Innovation Park No 9 Lizhishan Road Science City Guangzhou High tech Zone Guangdong P R China GUANGZHOU SANJING ELECTRIC CO LTD C6 75K T6 C6 100K T9 C6 110K T12 C6 125K T12 C6 50K T6 LV C6 60K T9 LV C6 70K T12 LV V1 0 广州三晶电气股份有限公司 2023 02 01 技术资料专用章 ...

Page 2: ...he instructions of this manual so that we can ensure delivery of our professional guidance and wholehearted service Customer orientation is our forever commitment We hope this document proves to be of great assistance in your journey for a cleaner greener world Please check for the latest version at www saj electric com Guangzhou Sanjing Electric Co Ltd The World s Leading Provider of Digital Ener...

Page 3: ...Contents 01 02 USER MANUAL SAJ SOLAR INVERTER ...

Page 4: ... read and fully understood all safety regulations contained in this manual can install maintain and repair the inverter Operators must be aware of the high voltage device 1 2 Safety Instruction 03 Safety Precautions CAUTION CAUTION indicates a hazardous condition which if not avoided can result in minor or moderate injury DANGER DANGER indicates a hazardous situation which if not avoided will resu...

Page 5: ...onnect PV array from inverter via an external disconnection device If there is no external disconnection device present wait until no more DC power is applied to the inverter Disconnect the AC circuit breaker or keep it disconnect if it is tripped and secure it against reconnection Do not touch non insulated parts or cables Do not touch non insulated parts or cables The installation service recycl...

Page 6: ...ents inside the inverter will release a lot of heat during operation Do not touch metal plate housing during operating An error has occurred Please go to Chapter 9 Troubleshooting to remedy the error This device shall not be disposed of in residential waste Please go to Chapter 8 Recycling and Disposal for proper treatments CE Mark Equipment with the CE mark fulfills the basic requirements of the ...

Page 7: ...of Products C6 series product is grid tied three phase inverter without transformer The product converts the DC generated by solar panels into AC which is in accordance with the requirements of public grid and send the AC into the grid Figure 3 1 shows the structural diagram of the typical application system of C6 inverter Figure 3 1 C6 series application Solar array C6 inverter AC Distribution bo...

Page 8: ...0 1000 600 200 180 2 Integrated 6 30 9 30 12 30 6 45 9 45 12 45 165 180 Max Input Voltage V MPP Voltage Range V Nominal Input Voltage V Startup Voltage V Min Input Voltage V Max Input Current A Max Short Circuit Current A Number of Strings per MPP Tracker Number of MPP Trackers DC Switch Rated AC Output Power kW Max AC Output Power kW Max AC Apparent Power kVA Rated AC Output Current A Max AC Outp...

Page 9: ...mmunication Port Communication Mode General Data Topology Operating Temperature Range Nighttime Power Consumption W Cooling Method Ambient Humidity Max Operating Altitude m Intelligent fan cooling 0 100 non condensing4000 3000 power derating RS232 RS485 OT DT Terminal Max 240 mm MC4 LED APP Bluetooth Wi Fi Ethernet 4G PLC Optional Non isolated 2 30 60 45 to 60 with derating General Data Model Nois...

Page 10: ...60 70 131 2 157 5 157 5 3 N PE 127 220 50 60 44 55 54 65 3 0 8 leading 0 8 lagging 3 3 183 7 144 3 183 7 6 9 12 Protection Model AFCI Protection PV String Current Monitoring Integrated Optional Optional Integrated Integrated Integrated Integrated Integrated Integrated Type II Type II Integrated Integrated Internal Temperature Detection Residual Current Monitoring Unit DC Insulation Resistance Dete...

Page 11: ...erating Altitude m 60 IP66 Wall mounting 660 1045 361 93 98 5 Standard 10 15 20 Optional IEC EN62109 1 2 EN61000 6 1 2 3 4 Ingress Protection Mounting Dimensions H W D mm Weight kg Warranty Year Certifications C6 50K T6 LV C6 60K T9 LV C6 70K T12 LV 4000 3000 Power Derating ...

Page 12: ...ed and are checked before delivery it is uncertain that the inverters may suffer damages during trans portation Please check the package for any obvious signs of damage and if such evidence is present do not open the package and contact your dealer as soon as possible The equipment employs natural convection cooling and it can be installed indoor or outdoor Vertical installation on eye level is re...

Page 13: ...due to overheating The ambient temperature should be between 40 C 60 C 40 F 140 F to ensure optimum operation Choose locations with sufficient air exchange Ensure additional ventila tion when necessary DO NOT install the inverter near any inflammable and explosive items 600mm 500mm 800mm 800mm 1000mm 21 22 Drill Holes and Place the Expansion Tubes Follow the given guides drill 3 holes in the wall ...

Page 14: ...cket Mount the Screws and the Mounting Bracket The brackets should be mounted in the mounting position by screws as below Mount the Inverter Carefully mount the inverter to the mounting bracket Make sure that the rear part of the equipment is closely mounted to the mounting bracket Mark the Positions of the Drill Holes of the Mounting Bracket The mounting position should be marked as below Drill H...

Page 15: ...voltage when exposed to sunlight Disconnect DC and AC circuit breakers before starting electrical connections Ensure all the cables have no voltage before conducting cable connection Item Name A DC Switch DC Input RS232 Communication RS485 Communication AC Output Ground Connection Ground Connection B C D E F G 25 26 5 WARNING Any improper operations during cable connection can cause device damage ...

Page 16: ...erter Inverter enclosure grounding connection Circuit Breaker Grid Monitoring Platform 2 3 4 5 6 Cable type Scope S Recommended grounding cable Spe External diameter mm Three core four core five core cable Four single core cable Spe S 2 14 32 38 66 95 240 Model Recommended circuit breaker rated voltage Recommended circuit breakerrated current C6 100K T9 C6 60K T9 LV C6 75K T6 C6 50K T6 LV C6 110K ...

Page 17: ...eter of the cables mm Scope 4 S 6 6mm 9mm 1 Insulated enclosure 2 Lock screw 3 Positive connector 1 Insulated enclosure 2 Lock screw 3 Negative connector 1 2 3 1 2 3 DANGER Dangerous to life due to electric shock when live components or DC cables are touched The PV panel string will produce lethal high voltage when exposed to sunlight Touching live DC cables results in death or lethal injures DO N...

Page 18: ...W2 C1 RT2 M9 M12 RT1 1 1 4 Insert the positive and negative connectors into positive cable and nega tive cable whose insulated enclosure has been stripped off and crimp them tightly with a wire crimper Make sure that the withdrawal force of the pressed cable is bigger than 400N 5 Plug in the pressed positive and negative cables into relevant insulated enclosure a click should be heard or felt when...

Page 19: ... connection Multiple inverter dry contact connection 2 LED indicator as the alarm fault indicator When relay is on normal open contact NO and no alarm fault occurs LED indicator is off When there is fault occurs relay is on normal close contact NC LED is on Emergency stop dry contact When DI contact and DI contact are shorted by external controlled switch the inverter will stop immediately COM1 NC...

Page 20: ...signal RS485 in RS485B differential signal GND shielded earthing point RS485 in RS485A differential signal RS485 in RS485B differential signal GND shielded earthing point RS485 B PE RS485 A RS485 B PE Terminal block Note When there are multiple inverters connected please connect a ter minating resistor between A1 and B1 by switching the RS485 DIP switch to ensure the communication quality A1 B1 P1...

Page 21: ...ace Display Ring Light LED Panel 1 LED Panel 2 Status Solid Green Breathing Mode Solid Red Breathing Mode Off Description The inverter is in normal on grid state The inverter is in initialization or waiting state An error occurs Software is upgrading in the inverter Power off Current power kW Error code Total yield kWh 6 Table 6 1 Interface description ...

Page 22: ...nd download this App Account Please use the installer account to login Select the initial setting Choose your corresponding country region and grid compliance please contact your local grid operator for which grid compliance to select Set the inverter time based on your location Connection setting Step 1 Log in to eSAJ Home if you do not have an account please register first Step 2 Go to the Tool ...

Page 23: ...h 37 Master Islanding Error 38 Master HW Bus Voltage High 39 Master HW PV Current High 40 Master Self Test Failed 41 Master HW Inv Current High Code Fault Information 42 Master AC SPD Error 43 Master DC SPD Error 44 Master Grid NE Voltage Error 45 Master Fan1 Error 46 Master Fan2 Error 47 Master Fan3 Error 48 Master Fan4 Error 49 Lost Communication between Master and Meter 50 Lost Communication be...

Page 24: ...Check if connection of the AC output grounding terminal is stable and reliable If the content mentioned as above is normal please contact your distributor or call SAJ technical support Check the connection status between the inverter and the grid and test whether the volt of the grid is stable or not if the above mentioned are in normal please contact your distributor or call SAJ technical support...

Page 25: ...inverter with moistened cloth with clear water only Do not use any cleaning agents as it may damage the components Heat Sink Cleaning Clean the heat sinks with dry cloth or air blower Do not clean the heat sink with water or cleaning agents Make sure there is enough space for ventilation of inverter 8 1 Routine Maintenance 8 ...

Page 26: ... 47 48 9 This device should not be disposed as residential waste An inverter that has reached the end of its life and is not required to be returned to your dealer it must be disposed carefully by an approved collection and recycling facility in your area ...